If any type of disinfectant has been used, follow the next procedure to dry the tank.
Remember that a correct maintenance lengthen the durability of the product.
Carefully release and open the interlocking vent valve (
Open 6
).
Wait until pressure in the tank becomes that of atmosphere (no air flows out at
that time)
Connect the Filling hose (2) to the Inlet quick connection (3).
Open the filling valve (
Open 4
) and
check that Liquid supply valve (10) is closed
.
Keep the filling hose (2) lower than the filling valve (4) and poor the remaining
liquid into a container using the filling hose (if exist). Dispose any liquid
according to the recommendations of the liquid manufacturer.
Fill up your SDR-F05A+ with drinkable water. Hold up the end of the filling
hose (2) and use the funnel (1) to fill the tank (5) with liquid
. Remember to
keep open the filling valve and the interlocking vent valve.
Always wear gloves and safety googles when filling the tank!
Do not overfill! This will damage the device.
Close the Filling valve (
Close 4
).
Close and lock the interlocking vent valve (
Close 6
).
Tilt the COUNTERFOG® SDR-F05A+ slightly to both sides
so as to drinkable
water is being mixed with the remaining disinfectant in the walls of the pressure
tank (5).
Open the interlocking vent valve (
Open 6
).
Open the filling valve (
Open 4
) and
check that valve 10 remain closed
. Keep the
filling hose (2) lower than the filling valve (4) and poor the water into a
container using the filling hose.
Disconnect the Filling hose (2) from the Inlet quick connection (3).
Open the filling valve (
Open 4
) and check the other valves remain closed
(6,10,16 and 17 closed)
.
Plug the equipment
to the 230 V supply line.
Press the ON button
of the KAESER icomp3 compressor (12) (
GREEN
) and
wait
for 12 minutes
to remove the moisture of the pressure tank (5) through the
filling valve (4).
Summary of Contents for SDR-F05A+
Page 1: ...COUNTERFOG SDR F05A USER MANUAL September 2020...
Page 9: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 9 3 2 COMPONENTS...
Page 11: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 11...
Page 12: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 12...
Page 13: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 13...