COUNTERFOG® SDR-F05A+
User Manual
COUNTERFOG® EBT de la UAH S.L.
18
7.3
POWER CONNECTION
Before making electrical connections carefully check that the voltage supplied is
compatible with the voltage marked on the data plate and that there are shortcut
and overcurrent as well as current default protections in service
For 125 Vac electrical supply, use an autotransformer 125V to 230V.
Double check that
all valves (4,6,10,16 and 17) are closed
.
Plug the equipment
to the 230 V supply line.
7.4
SWITCH ON AND PRESSURIZATION OF TANK
Double check that
all valves (4,6,10,16 and 17) are closed.
Press the ON button
of the KAESER icomp3 compressor (12) (
GREEN
).
KAESER i.Comp 3 compressor (12) is programmed to
automatically provide a
pressure of 10 bar in the tank (5)
-Check pressure gauge (8)-. If this program
has been modified, adjust tank’s pressure to 10 bar -please refer to KAESER
icomp3 (12) manual-.
Push button (+) on the KAESER i.comp 3 compressor (12) –on the left of the
display-
. This configuration minimizes pressure fluctuation in continuous
operation.