7.5
OPERATION
Double check that
all valves (4,6,10,16 and 17) are closed.
Carefully open Liquid supply valve (
Open 10
).
Hold the lance set
griping the actuator (gun) (18).
Point the actuator (gun) (18) to the floor
.
Open completely the Airline valve (
Open 17
).
Open progressively and carefully the liquid supply regulating valve (
Open 16
).
This will modify the size distribution of droplets in the fog.
Press the actuator (gun) (18)
and proceed to disinfection.