background image

 

 

 

COUNTERFOG® SDR-F05A+ 

USER MANUAL 

September 2020

 

Summary of Contents for SDR-F05A+

Page 1: ...COUNTERFOG SDR F05A USER MANUAL September 2020...

Page 2: ...1 TECHNICAL DATA 8 3 2 COMPONENTS 9 3 3 PACKAGE CONTENTS 14 4 ROOM PREPARATION 14 5 RECOMMENDED PERSONAL PROTECTION EQUIPMENT PPE 15 6 ROOM PREPARATION 15 7 OPERATING INSTRUCTIONS 16 7 1 POSITION 16...

Page 3: ...goods It provides a dynamic fog cone made of micrometric and submicrometric droplets of liquid disinfectant to be projected in air to catch up air borne matter dust aerosols spores etc By applying it...

Page 4: ...both outdoors and indoors Counterfog SDR F05A is intended for hospitals clinics public transport vehicles retail and residential commercial and industrial areas Risk of Damage Breathing fogs or mists...

Page 5: ...of the disinfectant with the material in the treated area and the protective measures for people in the area must be taken into account It is strictly forbidden to use flammable liquids that can prod...

Page 6: ...is liquid inside the tank check for leaks in the hydraulic circuit Do not plug in if electrical plug or parts are wet High electric shock hazard Do not overfill the tank as this can cause leakage and...

Page 7: ...ERFOG EBT de la UAH S L 7 The users must always have a copy of this Operation Manual at their disposal when operating the device and have read and understood all specific indications stated on the lab...

Page 8: ...sing dimensions 84x63x134 cm Noise level 92 dB 1m Total weight empty 43 10 kg Total weight filled 57 47 kg Working Pressure 10 bar Maximum operating pressure 11 bar Maximum admissible pressure 12 bar...

Page 9: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 9 3 2 COMPONENTS...

Page 10: ...valve 5 Pressure tank 6 Interlocking vent valve 7 Safety valve 8 Pressure gauge 9 Check valve 10 Liquid supply valve 11 Counterfog F1 6 Nozzle for massive nanometric fog generation 12 KAESER i Comp 3...

Page 11: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 11...

Page 12: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 12...

Page 13: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 13...

Page 14: ...wished the ventilation system be turned off for the duration of the fogging process Cover any smoke detectors Do not point nozzle towards smoke detectors and check with facility management to take ap...

Page 15: ...Please consult the indications of the liquid producer and your Health Safety responsible General recommended Personal Protection Equipment will include the following Respirator full face mask with CB...

Page 16: ...mattresses from beds and tilt them on their sides Assure all personnel have evacuated the room before fogging Remove plants animals beverages and food Close windows and doors of the room All entrance...

Page 17: ...ectant liquids usually need to be diluted in water following the instructions of their producer You can fill your SDR F05A with the diluted solution or alternatively to fill it with the several compon...

Page 18: ...10 16 and 17 are closed Plug the equipment to the 230 V supply line 7 4 SWITCH ON AND PRESSURIZATION OF TANK Double check that all valves 4 6 10 16 and 17 are closed Press the ON button of the KAESER...

Page 19: ...Liquid supply valve Open 10 Hold the lance set griping the actuator gun 18 Point the actuator gun 18 to the floor Open completely the Airline valve Open 17 Open progressively and carefully the liquid...

Page 20: ...ed under 1 micron from air the size of the fog must be of the same order Therefore the liquid supply regulating valve 16 must be open just to the point in which a light fog turns to be visible2 Risk o...

Page 21: ...tion unplug the COUNTERFOG SDR F05A equipment move it to a safe place and proceed to depressurization Close the Liquid Supply Regulating Valve Close 16 the Air Line Valve Close 17 and the Liquid suppl...

Page 22: ...ng hose 2 from the Inlet quick connection 3 Open the filling valve Open 4 and check the other valves remain closed 6 10 16 and 17 closed Plug the equipment to the 230 V supply line Press the ON button...

Page 23: ...fill the tank 5 with liquid Remember to keep open the filling valve and the interlocking vent valve Always wear gloves and safety googles when filling the tank Do not overfill This will damage the dev...

Page 24: ...the kind of disinfectant used venting is mandatory People can enter the room only when the fog is dissipated Do not forget to turn on the Fire Detection System of the facility again after the whole d...

Page 25: ...from severe impact or shock Do not tip the SDR F05A on its side at any time unless completely empty and dry 11 TROUBLESHOOTING Anomaly Possible Cause Solution Device does not work Check power supply C...

Page 26: ...nd in advance check defects caused by the means it deems appropriate without the Purchaser being able to hinder the actions of the persons designated by COUNTERFOG to verify such non conformity COUNTE...

Page 27: ...NTERFOG j repair of the damage or damage from the use of the Products in places environments or purposes in which there are no adequate factors conditions or characteristics to obtain optimal performa...

Page 28: ...State authority or Buyer or Buyer s contractors or suppliers COUNTERFOG s total liability for all claims of any class arising out of or relating to the conclusion performance or breach of the Contract...

Page 29: ...d protect the environment to prevent environmental pollution and to improve the recycling of raw materials a directive was issued by the European Commission which states that all electrical and electr...

Page 30: ...are the viricide products authorized and registered in Spain that have proven effective against viruses in accordance with the UNE EN 14476 standard Antiseptics and chemical disinfectants Quantitative...

Page 31: ...IC SF x x x TOTAL SHOCK SF x x x TERMINAL FORTE SR x x x BIOQUELL HPV AQ x x x Vaprox Hydrogen Peroxide Sterilant x x Vaprox 59 Hydrogen Peroxide Sterilant x x DUROX LRD x x x DYBAC NT2G x x x x WA 52...

Page 32: ...salt 49 7 10 49 oxygen available Specialized professional staff 10 gr product 1 l of water for 50 75 m Air disinfection Fogging with the product diluted in water Recommended safety period 12 hours OX...

Page 33: ...ntact disinfection surfaces and fabrics by conventional spraying of the product from a distance of about 25 cm Aerial disinfection for use by specialized personnel aerial spraying of the product OX VI...

Page 34: ...nce or fogging with the pure product Contact time 30 min Safety period of 24 hours AMBIDOX 25 19 20 40 90 10190 Didecyldimethyl ammonium chloride 6 93 Professional staff Consult with the manufacturer...

Page 35: ...cs and requirements of each installation roughly 5 10 ml m3 Contact disinfection surfaces and equipment by spraying immersion wiping or mopping with the product diluted in water respecting the contact...

Page 36: ...Glutaraldehyde 2 5 Specialized professional staff Undiluted at the rate of 12 min 100 m3 Contact disinfection surfaces and equipment by fogging with the pure product Apply in absence of people Safety...

Page 37: ...term of security of 4 hours BIOQUELL HPV AQ 17 20 40 90 08737 Hydrogen peroxide 35 85 Specialized professional staff Undiluted Air disinfection apply the pure product with automated vaporization syste...

Page 38: ...l Commercial and Institutional environments Disinfection by a vaporized hydrogen peroxide VHP unit National Registry of products for the disinfection of materials and equipment in contact with food fe...

Page 39: ...aces and equipment by spraying and or washing with the product previously diluted in water Disinfection of air conditioning equipment and ducts In air conditioning equipment use will be only punctual...

Page 40: ...of 60 min Recommended safety period 24 hours Specialized professional staff 1 Air disinfection Fogging with the product diluted in water with a contact time of 60 min Recommended safety period 24 hou...

Page 41: ...l staff Undiluted or diluted consult the manufacturer depending on the characteristics and requirements of each installation Air disinfection Nebulization or thermonebulization with the pure product o...

Page 42: ...Specialized professional staff Undiluted Air disinfection Spraying or fogging with the pure product DESCOL 16 20 40 90 08635 HA Ethanol 71 Phenoxyethanol 2 1 N 3 aminopropyl Ndodecylpropane 1 3 diamin...

Page 43: ...20 40 90 09514 HA Hydrogen peroxide 5 Silver 0 00415 Professional staff Undiluted at the rate of 80 ml m2 Contact disinfection for use Surfaces and equipment by spraying scrubbing brushing wiping or i...

Page 44: ...0 40 90 10220 HA Decildimethylammoniu m chloride 4 5 Professional staff 5 Contact disinfection surfaces and equipment by spraying or manual washing with the product diluted in water respecting the con...

Page 45: ...ces and equipment by spraying and or washing with the product previously diluted in water Disinfection of air conditioning equipment and ducts In air conditioning equipment use will be only punctual w...

Page 46: ...y mechanical application with a dispenser VAPROX 550 DES Hydrogen peroxide 35 Professional staff Undiluted Air disinfection apply the pure product with an automated vaporization system On the other ha...

Page 47: ...de 2 General public Undiluted Contact disinfection Surfaces by spraying with the pure product NDP AIR TOTAL GREEN 17 20 40 05645 Didecyldimethyl ammonium chloride 0 46 2 phenoxyethanol 0 1 Specialized...

Page 48: ...umber Active Substance User Manufacturer s recommended concentration Manufacturer s recommended application procedure SANYTOL MULTI PURPOSE CLEANER 12 20 40 05237 Didecyldimethyl ammonium chloride 0 5...