2-2. Electrical Performance
Specification Model
No.
Item
S1500-112 S1500-124 S1500-148 S1500-212 S1500-224 S1500-248
Continuous Output Power
1500W
Surge Rating
2000W
Input
Voltage
12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 115 / 120V ± 3%
200 / 220 / 230 / 240V ± 3%
Frequency
(Switch Selectable)
50/60Hz +/- 0.05%
Peak Output Current
25A
11A
Efficiency
(full
load) 85% 87% 88% 86% 89% 90%
No Load Current Draw
≦
1.5W Saving Mode
Output Waveform
Sine Wave <3% THD
Output Voltage Regulation
100 / 110 / 115 / 120V
RMS –10%/+4%
200 / 220 / 230 / 240V
RMS –10%/+4%
Input Voltage Regulation
10-16 VDC 20-32 VDC 42-62 VDC 10-16 VDC 20-32 VDC 42-62 VDC
Protection
Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input
Voltage, Over Temperature.
Power Saving Recovery
Time
5 Second
Interface Control Port
RS-232C With Baud Rate 1200, 2400, 4800 (Switch Selectable)
Remote Control Unit
Optional
Safety UL458
EN60950
EMC
FCC Class B
EN50081-1:1992
EN50082-1:1992
EN55022B:1994
EN61000-4-2:1995
EN61000-4-3:1996
ENV50204:1995
e-Mark
e13-020932
Operating Temperature
Range
0-40
℃
Storage Temperature Range
-30
℃
to 70
℃
Dimensions
390 (L) x 275 (W) x 105 (H) mm / 15.4 (L) x 10.8 (W) x 4.1 (H) Inch
Cooling
Thermostatically controlled cooling fan
( 55
℃
ON , 45
℃
OFF)
Weight
7.0kgs / 15.5 lbs.
5
Summary of Contents for S1500-112
Page 1: ...S1500 Series Pure Sine Wave Inverter User s Manual...
Page 7: ...2 3 Mechanical Drawings 6...
Page 33: ...10 1 FCC Class B Declaration of Conformity 32...
Page 34: ...10 2 CE EMC EN55022B Declaration of Conformity 33...
Page 35: ...10 3 CE LVD EN60950 Declaration of Conformity 34...
Page 36: ...10 4 e mark e13 020932 Declaration of Conformity 35...