8-2-2-5. To query status command
Format: STUS ?
Illustration: Don’t need to add any of parameter. To
respond the result be hexadecimal code replaced by 2
ASCII codes that is between 00 ~ FF (0~255), then convert
the Hex code to the binary digit after obtaining 8 bytes digit
that can be one of following:
“B2 ” OLP
“B4 ” OTP ( Loading > 100% / 3 min )
“B0 ” UVP ( LSB ) ( Loading > 110% )
“B1
”
OVP
“B3 ” FLP
“B5 ” BATT Too Low
“B6 ” BATT Too High
“B7
”
LOAD
Too High ( MSB )
8-2-2-6. To query battery level command
Format: BATT ?
Illustration : Don’t need to add any of parameter.
To respond the result be Hexadecimal code replaced by 2
ASCII codes and is between 00 ~ 0B, then convert into
decade digit after obtaining a digit, between 0~11, that
can be one of following:
Hex
code
Decade
code
Indication
00
0
LED 1 glows blinking to indicate low
voltage
01
1
LED 1 glows solid.
02
2
LED 2 glows solid.
03
3
LED 3 glows solid.
04
4
LED 4 glows solid.
05
5
LED 5 glows solid.
06
6
LED 6 glows solid.
07
7
LED 7 glows solid.
08
8
LED 8 glows solid.
09
9
LED 9 glows solid.
0A
10
LED 10 glows solid.
0B
11
LED 11 glows blinking to indicate over
voltage
24
Summary of Contents for S1500-112
Page 1: ...S1500 Series Pure Sine Wave Inverter User s Manual...
Page 7: ...2 3 Mechanical Drawings 6...
Page 33: ...10 1 FCC Class B Declaration of Conformity 32...
Page 34: ...10 2 CE EMC EN55022B Declaration of Conformity 33...
Page 35: ...10 3 CE LVD EN60950 Declaration of Conformity 34...
Page 36: ...10 4 e mark e13 020932 Declaration of Conformity 35...