9. Appendices C
9-1. Remote
Control
Option
:
System Configuration
:
9-1-1. Plug the 9-pin D-SUB connector of the remote controller in the
RS-232 port of the Inverter.
9-1-2. Check the setting of DIP-SW S5 & S6, The communication BAUD
RATE should be set to 4800bps (S5 & S6 OFF).
LED Indications
:
9-1-3. Turn on the switch of the Inverter, There will be two short beep
sounds from the Inverter. All LEDS will be ON and, one second
later, there will be a short Beep sound. The amber, green and
red LEDS of remote controller will be on for 0.5 second then off
sequentially. The Inverter is then in the OFF mode.
The amber LED will be blinking every 2~3 seconds.
9-1-3-1. Remote Controller LEDS
:
Color / Status
Power Saving
Power Output
Green “ON”
Enable
ON
Green “Blinking”
Enable
OFF
Amber “ON”
Disable
ON
Amber “Blinking”
Disable
OFF
Green
:
Power saving enable
。
Amber
:
Power saving disable
。
ON
:
Power On
。
Blinking
:
Power Off
。
26