4
IMPORTANT SAFETY INFORMATION ABOUT
PROPANE (LP) GAS
l
The cylinder supply system must be arranged for vapor withdrawal.
l
This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a
building, garage or any other enclosed space.
l
When this appliance is not is use, the gas must be turned off at the supply cylinder.
l
Storage of this appliance indoors is permissible only if the cylinder is disconnected and removed
from the appliance.
l
Cylinders must be stored outdoors in a well-ventilated area out of the reach of
children .Disconnected cylinders must have protective caps installed and must not be stored in a
building, garage or any other enclosed areas.
l
Change the gas cylinder in an amply ventilated area, away from any ignition source (candle,
cigarettes, other flame producing appliances.
l
Check that the regulator seal is correctly fitted and able to fulfill its function.
l
Do not obstruct the ventilation holes of the cylinder housing.
l
Use only the type of gas and the type of cylinder specified by the manufacturer.
l
In case of violent wind particular attention must be taken against tilting of the appliance.
This appliance is for use only with a 5KG Patio Gas Cylinder unless converted for use with Natural
Gas with the provided gas conversion kit. The cylinder must be equipped for a clip-on regulator. See
Figure 1.
Figure 1
SPECIFICATIONS
Appliance Category II2H3P
Appliance Type A
Country GB
INPUT
High Fire
Low Fire
Propane(G31)
12.5 kW Net 893 gr per hr.
9.0 kW Net 630 gr per hr.
Natural Gas (G20)
13.5 kW Net
5.8 kW Net
Propane Regulator Pressure
37 mBar
1.95 mm Injector, Red
Natural Gas Inlet Pressure
20 mBar
4.00 mm Injector, Brass
Clearances to combustible
surfaces
Sides 60.96 cm / 24 in
Top: 182.88 cm / 72 in
Marking of red on the injector indicates that the size of injector is 1.95mm