46
MYDENS
COSMOGAS
7 - USE
Parameter
Description of the parameter
M.U.
1001
Central heating supply temperature
°C
1002
Domestic hot water temperature (or indirect water heater temperature, if present)
°C
1003
No function
/
1004
External temperature (visible when an external temperature sensor is installed)
°C
1005
Central heating supply temperature (safety sensor)
°C
1006
Fumes temperature
°C
1007
Central heating return temperature
°C
1008
Ionisation current
uA
1009
Status of the pump inside the boiler
ON/OFF
1010
Status of the central heating side diverter valve
(ON = in central heating mode; OFF = in domestic hot water mode)
ON/OFF
1011
Status of the central heating side diverter valve (ON = in D.H.W. mode; OFF = in central heating mode)
ON/OFF
1012
Central heating supply temperature calculated via the external sensor
°C
1013
Status of the room thermostat contact
(OPEN = no central heating request; CLOSED = presence of central heating request)
OPEN/CLO-
SED
1014
Fumes temperature (safety sensor)
°C
1040
Current rotation speed of the fan
rpm
1041
Fan rotation speed on ignition
rpm
1042
Fan rotation speed in minimum power mode
rpm
1043
Fan rotation speed in maximum power mode
rpm
1051
Latest block condition recorded (Loc) (see chapter 7.19.1)
/
1052
Latest error condition recorded (Err) (see chapter 7.19.2)
/
1053
Number of times the burner has lost the flame
n°
1055
Number of failed burner ignitions
n°
1056
Number of hours worked in central heating mode
h x 10
1057
Number of hours worked in domestic hot water mode
h x 10
1058
Numero di giorni di lavoro del bruciatore
days
1059
Interval of time between the last two blocking errors (Err)
1
value in minutes;
2
value in hours;
3
value in days;
4
value in weeks;
1060
Interval of time between the last two blocks (Loc)
1061
Current rotation speed of the domestic hot water turbine
rpm
1062
Current domestic hot water flow rate
l/min
7.17 - “User menu”
Press the RESET key for 2 seconds to access the “User
menu”. The visual display “M” in figure 7.1, starts to show
parameter
1001
to inform the use of the mode change.
Using the
and
keys, scroll the parameters
contained in the menu.
Just press the RESET key again for 2 seconds to exit the
menu.
The parameters in this menu are display only and cannot be
modified via the same.
If no key is pressed for more than 60 seconds, the menu is
exited automatically.
The following parameters can be queried in this menu:
Summary of Contents for MYDENS
Page 67: ...67 MYDENS COSMOGAS 8 MAINTENANCE...
Page 74: ......
Page 75: ......
Page 76: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com...