MYDENS TECHNICAL DATA
M.U.
15
24
34
Central heating maximum pressure “PMS”
bar
3
3
3
Central heating minimum pressure
bar
0,5
0,5
0,5
D.h.w. circuit maximum pressure
bar
/
7
7
D.h.w. minimum pressure
bar
/
0,3
0,3
Expansion tank pre-load pressure
bar
1
1
1
Expansion tank capacity
lt
10
10
10
Rated power supply voltage
V
230
230
230
Rated power supply frequency
Hz
50
50
50
Absorbed electric power
W
120
120
120
Electric protection rating
IPX4D
IPX4D
IPX4D
Elec. pow. of the generator aux. positioned before firebox
W
70
70
70
Elec. pow. of the generator aux. at min.pow. positioned before firebox
W
30
30
30
Elec. pow. of the generator aux. positioned after firebox
W
50
50
50
Elec. pow. of the generator aux. at min.pow. positioned after firebox
W
50
50
50
Power absorbed by the auxiliaries at rated power
W
50
50
50
Power absorbed by the auxiliaries at intermediate load
W
20
20
20
Power absorbed by the auxiliaries at zero load
W
1
1
1
Electric power absorbed by the pump
W
50
50
50
Fumes pipe diameter (split)
mm
80 o 60
80 o 60
80 o 60
Fumes pipe max. length (split) (80)
m
40
40
25
Fumes pipe max. length (split) (60)
m
15
15
10
Fumes pipe diameter (coaxial)
mm
60/100
60/100
60/100
Fumes pipe max. length (coaxial)
m
10
10
10
Equivalent length of a bend
m
Curva a 45° = 0.5m, curva a 90° =1m
Weighted CO (0% O2 with nat Gas)
ppm
1
8
15
Weighted NOx (0% O2 with nat Gas) (class 5 EN 483 and 297)
ppm
11
13
17
CO2 (%) at minimum/maximum power
Nat Gas
%
8,5/9,0
8,5/9,0
8,5/9,0
CO2 (%) at minimum/maximum power
LP Gas
%
10/10,5
10/10,5
10/10,5
O2 (%) at minimum/maximum power
Nat Gas
%
5,5/4,8
5,5/4,8
5,5/4,8
O2 (%) at minimum/maximum power
LP Gas
%
5,6/4,8
5,6/4,8
5,6/4,8
Maximum recirculation of fumes allowed in the event of wind
%
10
10
10
Fumes maximum temperature at boiler outlet
°C
75
75
75
Fumes minimum temperature at boiler outlet
°C
30
30
30
Mass flow of the fumes
kg/h
25,4
42,3
59
Mass flow of the fumes at minimum power
kg/h
5,3
5,3
7,2
Head available at exhaust
Pa
60
60
60
Maximum temperature of the combustion agent air
°C
50
50
50
Maximum CO2 content in the combustion agent air
%
0,9
0,9
0,9
Fumes maximum temperature for overheating
°C
90
90
90
Max. negative pressure allowed in the fumes exhaust/intake system
Pa
60
60
60
Condensate maximum flow rate
l/h
1,9
3,2
4,3
Condensate average acidity
PH
4
4
4
Operating environment temperature
°C
0 ; +50
0 ; +50
0 ; +50
Weight of the boiler
B
kg
36
36
38
C
kg
34
34
36
P
kg
/
36
38
9 - TECHNICAL DATA