5 - USE

After the first start-up and during use, the thermostat shows 

the room temperature, the internet connection status (top right 

icon) and if the thermostat is on heating call or not (stylized 

flame on the left of the display).

5.1 Desired Environment Temperature (setpoint temperatures)

To adjust the desired room temperature (or setpoint) simply turn 

the thermostat outer ring. The thermostat will try to keep the 

set temperature as accurately as possible. Rotate the ring in a 

clockwise direction to increase the setpoint or anticlockwise to 

decrease it. After 5 sec. The measured temperature appears 

again on the screen.

 

NOTE: If a schedule of time bands has been previously set 

via smartphone or tablet, manual modification of the desired 

temperature will take effect up to the time change determined 

by the aforementioned programming.

5.2 Limitation of setpoint temperatures

Basic Cosmobit can set the setpoint temperature in a range between 5 ° C and 35 ° C.

If you want to limit this adjustment range, proceed as follows:

NOTE: the setpoint temperature limitation, as set on Cosmobit, has priority to the settings from the App.

Turn the adjustment ring counterclockwise until 5 ° C appears. 

Then press the button hidden just below the display for 10 

seconds as shown in the figure.

The maximum value of 35 ° C appears. Using the adjustment 

ring, bring this value to the maximum desired value. It is not 

necessary to confirm the operation. This will be the maximum 

settable temperature.

Press the right button again to access the minimum value. 

Also bring this to the desired value. This will be the minimum 

settable temperature.

1

2

1. - Direction of rotation to lower the temperature;

2. - Direction of rotation to raise the temperature;

COSMOBIT

Summary of Contents for CosmoBIT

Page 1: ...62403808 R01 17 12 2018_UK CosmoBIT INSTALLATION USE AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...r power supply 7 1 8 Boiler settings and operation 8 1 9 Check connection between boiler and Cosmobit 8 2 COSMOBIT GATEWAY CONNECTION AND CONFIGURATION OF INTERNET CONNECTION 9 3 CREATION OF THE ACCOU...

Page 4: ...ower strictly necessary to satisfy the room temperature optimizing gas consumption Data communication also allows the display in the thermostat of any errors present in the boiler itself When Cosmobit...

Page 5: ...to the wall Screws and dowels are included in the supply 6 7 8 9 4 5 1 2 3 1 Avoid drafts 2 Do not place on a heat source 3 Do not place where reachable by direct sunlight 4 Remove the adjustment ring...

Page 6: ...to the thermostat 1 5 Refit the thermostat to its base 1 6 Connection to the boiler ATTENZIONE Remove the power supply to the boiler 16 13 14 15 10 11 12 10 Cable min 0 15 mm2 max 0 75 mm2 11 Cable c...

Page 7: ...osmobit will be connected to the OT terminals 7 8 present in the boiler terminal box 1 7 Restore the boiler power supply The thermostat will now be operational Before the room temperature is displayed...

Page 8: ...Mode 1 In this mode the external probe must be installed on the boiler The flow temperature is calculated based on the climatic curve set on the boiler The boiler starts or stops whenever the tempera...

Page 9: ...connected to the Cosmobit First make sure that the distance is not excessive In case of persistence of the red led even at short distances proceed with a new binding between the 2 devices see chapter...

Page 10: ...ation of the Cosmobit remotely and set the time slots for the whole week Login user name and password are those chosen in chapter 3 1 3 2 Installation Name After completing the registration and activa...

Page 11: ...y press the button below the display on the right side again see step b above The Cosmobit will send a request to connect to the gateway confirmed by the icon blinking at the top right e if the connec...

Page 12: ...ffect up to the time change determined by the aforementioned programming 5 2 Limitation of setpoint temperatures Basic Cosmobit can set the setpoint temperature in a range between 5 C and 35 C If you...

Page 13: ...will be less economical than the standard one Dopo aver premuto nuovamente il pulsante destro la temperatura viene visualizzata in modalit OFF Utilizzare l anello di regolazione per portarlo al valore...

Page 14: ...bol the setpoint is blocked for an indefinite period Function settable only through APP Stop symbol the thermostat is off for an indefinite time Function settable only through APP ATTENTION The last s...

Page 15: ...eck the manual of the appliance to verify that it has been followed correctly Defective thermostat The thermostat must be replaced Communication error Check the power supply of the internet gateway Co...

Page 16: ...COSMOGAS s r l Via L da Vinci 16 47014 MELDOLA FC ITALY info cosmogas com www cosmogas com...