OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS

 

 

l

 

Remove the gratings, the burner covers and the knobs; 

l

 

Using a wrench substitute the nozzle injectors “J”(fig:5.4-5.5) 
With those most suitable for the kind of gas for which it is to 

Be used. 

 
The burner are conceived in such a way so as not to require the   
regulation of the primary air. 
 

REGULATING THE BURNER MINIMUM SETTING 

 

When switching from one type of gas to another. the minimum     
Flow rate need also be correct: the flame should not go out even   
When passing suddenly from maximum to minimum flame.   
To regulate the flame follow the instructions below:     
 

l

 

Light the burner 

l

 

Set the gas valve to minimum 

 

On gas valves provided with adjustment screw in the center of the shift   
(fig. 5.6).Using a screwdriver with max, diameter 3 mm. turn the screw   
inside the tap until the correct setting is obtained.     

 

For LP/PROPANE gas, tighten the adjustment screw completely. 
 
After regulation repeat the operation indicated in paragraph “2. 
Pressure regulator” on page 12. 
If the cooktops has been disconnected and then connected again to the gas   
supply line repeat the operations indicated in paragraph “5. 
Leak Testing” on page 14. 

 

 
 
 
 
 

 
 
                                                                                                                                                 
 
 
 

 

TOOL NEEDED 

 

A=T-handle wrench 
B=wrench 
C=screwdrive

Summary of Contents for COS-VA-S950M

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS Carefully read the following Important information redarding installation safety and maintenance Keep these instruction for future reference...

Page 2: ...He will issue you with a gas certificate A manual gas shut off valve must be installed in the gas supply ahead of the appliance in the gas stream for safety and ease of service Do not store or use ga...

Page 3: ...o could play with old appliances l The appliance should be installed and all the gas electrical connections made by a qualified engineer in compliance with local regulations in force and following the...

Page 4: ...NTS 1 Auxiliary A 2 Rapid R 3 Semi rapid SR 4 Triple flame T 5 Hotplate H CAUTION If the burner flames are accidentally extinguished turn the gas off at the control knob and wait at least 1 minute bef...

Page 5: ...rate push in and hold the knob until the flame has been lit fig 2 2 If after 15 seconds the burner has not lit stop operating the device and open the compartment door and or wait at least 1 min befor...

Page 6: ...port may scratch the hob STAINLESS STEEL ELEMENTS Stainless steel parts must be rinsed with water and dried with a soft and clean cloth or with a chamois leather For difficult dirt use a specific non...

Page 7: ...rious problems In appliances with electric ignition check that the electrode S fig 3 1 is always clean to ensure trouble free sparking The ignition plug must be very carefully cleaned CORRECT POSITION...

Page 8: ...Screwdriver Wrench T handle wrench Tape measure Angle hexagon key Pencil Adjustable pliers Adjustable wrench Burner and Nozzle Specifications Liquid Towngas Burner Thermal Power Nozzle Flow Thermal Po...

Page 9: ...d ventilation air 8 Disconnect the electrical supply to the appliance before servicing 9 When removing appliance for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply...

Page 10: ...ION INTO THE CABINET Please take the cut out size according to the cooktops dimension 34 20 20 17 7 16 1 31 33 18 9 29 21 3 23 6 22 18 9 21 3 min 2 min 2 min 2 min 21 3 min 1 6 min 1 6 min 1 6 min 1 8...

Page 11: ...ter height 3 The maximum upper cabinet depth recommended is 13 330mm Wall cabinet above the cooktops must be a minimum of 30 762mm above the countertop for a width of minimum 11 13 32 290mm it has to...

Page 12: ...reached quickly in the event of an emergency Do not block access to the shutoff valve The valve is for turning on or shutting off gas to the appliance 2 Pressure Regulator figures 5 2 a AlI heavy dut...

Page 13: ...13 GAS CONNECTION SPECIFICATION...

Page 14: ...or is recommended for connecting this cooktops to the gas supply line Do not kink or damage the flexible connector when moving the cooktops The pressure regulator has 3 8 NPT female pipe threads You w...

Page 15: ...ssed in hundredths of a millimeter are marked on the body of each injector SETTING THE PRESSURE REGULATOR Fig 5 3 Attention The regulator is pre adjusted for both valves Aside from the turning of the...

Page 16: ...When passing suddenly from maximum to minimum flame To regulate the flame follow the instructions below l Light the burner l Set the gas valve to minimum On gas valves provided with adjustment screw i...

Page 17: ...ded ground method For your personal safety this cooktops must be grounded This cooktops is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a matchin...

Page 18: ...18 WIRING DIAGRAM IGNITION...

Reviews: