background image

THIS APPLIANCE MUST BE INSTALLED IN
ACCORDANCE WITH THE RULES IN FORCE AND
USED ONLY IN A SUFFICIENTLY VENTILATED
SPACE.

The Rayburn 200G/L Gas-Fired Cooker provides cooking
facilities only. A single atmospheric gas burner is
thermostatically controlled at cooking rates, and operates
at a low bypass rate when idling.
The exhaust flue connection of the appliance is in Open
Flue form, operating on natural draught.
Facilities included on the cooker are, a heat graduated
hotplate, main oven and lower oven. A timing programmer
is also available, as an optional extra.

Gas connection 15mm O.D. copper.
Open flue outlet 100mm min.
Electric Supply 50Hz 3 amp fused 230V.
Weight of Appliance 275Kg.

In your own interests, and that of safety, all gas
appliances should be installed by competent persons, in
accordance with the regulations in force.

Appliance

The appliance must be installed on a solid level floor or
base of incombustible material which is capable of
supporting the total weight.

Location

The location chosen for the appliance must permit
installation and the provision of a satisfactory flue and an
adequate space for servicing and air circulation around
the appliance. See Section - Installation of Appliance -
General.

REMEMBER, when replacing a part on this appliance,
use only spare parts that you can be assured conform to
the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not
clearly authorised by AGA.

Installation and Servicing Instructions
for Rayburn 200G/L
Gas Fired Cooker

FOR USE IN GB & IE

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE APPLIANCE

1

01/10 EINS 510974

[email protected]

INTRODUCTION

INSTALLATION INSTRUCTIONS

Technical Specification

Natural Gas

Heat Input

5.6kW

Pressure

G20

20mbar

G25

25mbar

Injector Size

1.82 Bray 460

Pilot Size

38/36A

LP

Heat Input

6.3kW

Nominal Rate

G31 Propane

489 g/h

G30 Butane

497 g/h

Inlet Pressure

G31 Propane

37mbar

G30 Butane

28mbar

Injector Size

1.27 Bray 220

Pilot Size

4209

Consumer Protection

As responsible manufacturers we take care to make sure that our
products are designed and constructed to meet the required safety
standards when properly installed and used.

IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY.

Any alteration that is not approved by AGA, could

invalidate the approval of the appliance, the warranty and could also
infringe the current issue of the statutory requirements.

IMPORTANT:

This appliance could contain any of the materials that are indicated
below. It is the Users/Installers responsibility to ensure that the 
necessary personal protective clothing is worn when handling, where
applicable, the pertinent parts that contain any of the listed materials
that could be interpreted as being injurious to health and safety, see 

below for information.

Firebricks

– when handling use disposable gloves.

Fire cement 

– when handling use disposable gloves.

Glues and sealants

– exercise caution – if these are still in liquid

form use face mask and disposable gloves.

Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil

– may be harmful if inhaled, may be irritating to skin,

eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product reduce dust with water spray, ensure
that parts are securely wrapped.

Summary of Contents for 200 G

Page 1: ...E APPLIANCE 1 01 10 EINS 510974 raywarranty aga web co uk INTRODUCTION INSTALLATION INSTRUCTIONS Technical Specification Natural Gas Heat Input 5 6kW Pressure G20 20mbar G25 25mbar Injector Size 1 82 Bray 460 Pilot Size 38 36A LP Heat Input 6 3kW Nominal Rate G31 Propane 489 g h G30 Butane 497 g h Inlet Pressure G31 Propane 37mbar G30 Butane 28mbar Injector Size 1 27 Bray 220 Pilot Size 4209 Consu...

Page 2: ... A flue pipe constructed in a to c should form the initial connection to lined chimneys Where a chimney is to be used which is not composed of or lined with a non porous acid resistant material it should be lined with a stainless steel flexible flue liner The internal diameter of the liner must be not less than 100mm and the number of joints must be kept to a minimum If the flue liner is not to be...

Page 3: ...grammer is available which will provide a timing feature to switch the main oven to the desired temperature setting as and when required See Fig 3 13m3 h of fresh air is required 60m3 h of fresh air is required THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH REGULATIONS IN FORCE General The appliance is floor mounted and must have the following minimum clearances for servicing installation Bet...

Page 4: ...g care not to damage the enamelled painted components of the floor covering in the room and insert suitable rollers beneath the base plate to aid positioning of the appliance When in position remove rollers and continue assembly NOTE IF THE REAR WALL IS OF COMBUSTIBLE MATERIAL THERE MUST BE AN AIR GAP OF 25mm BETWEEN THE WALL AND REAR OF APPLIANCE FIT REAR DISTANCE BRACKET AS SHOWN IN FIG 5 2 Asse...

Page 5: ...is in line with pipework 5 Turn the control knob B to the ignition symbol and depress it fully 6 Keeping control knob B depressed fully simultaneously press Piezo Spark Generator C repeatedly until the pilot flame lights This is visible through the sight glass F Fig 7 A few seconds must be allowed for the gas to reach the pilot burner 7 Continue to hold down Control Knob B for at least 15 seconds ...

Page 6: ...6 Fig 7 ...

Page 7: ...ow cooking load or idling conditions and the thermostat set to give the appropriate oven conditions when cooking see the Rayburn Cook Book for recipes The cooker burner provides heat for two ovens and hotplate A main gas service cock is incorporated below the cooker burner control valve Operation The burner K has a permanent pilot light H protected by a flame supervision valve Turning ON the main ...

Page 8: ...lean Heat Exchanger and Flueways a Replace the main and pilot burner assembly as previously described b Place a layer of paper on combustion chamber baseplate c Examine insulation panels for any sign of deterioration replace if necessary d Remove layer of paper with fallen debris e Check that oven top is free of deposit and brush in between ribs on hotplate underside f Examine soft rope seal locat...

Page 9: ...ufficiently to enable the phial to be removed from its clips push the phial towards the rear of the oven to release it from the front bracket j The thermostat can now be removed k Straighten an equivalent length of capillary on the new thermostat taking care when doing so not to kink it l Feed the capillary back through the front tube into the oven and relocate the capillary in the support bracket...

Page 10: ...10 Fig 8 ...

Page 11: ...11 ...

Page 12: ...licy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described at any time Manufactured by AGA Station Road Ketley Telford Shropshire TF1 5AQ England www rayburn web co uk www agacookshop co uk www agalinks com ...

Reviews: