CT1001/CT1002 Touchscreen Programmable Thermostat
Installer Setup
Name
Settings
Notes
Initial
Setting
Record
Temperature
Control in
Cool
1-less aggressive temperature control
(could cause temperature undershoot).
2-Standard temperature control in cooling
(factory setting).
3-more aggressive temperature control
(could cause temperature overshoot).
Applies to recovery ramp.
Choose 1 if getting temperature
overshoot.
Choose 3 if getting temperature
undershoot.
Temperature
Display
Offset
-3°F (-1.5°C)
-2°F (-1°C)
-1°F (-.5°C)
0°F (0. °C) (no difference in displayed
temperature and actual room
temperature )
1°F (.5°C)
2°F (1°C
3°F (1.5°C)
Reset Thermostat
0-no thermostat reset.
1-resets all Installer Setup Options to
default values and resets schedule to
default setting.
Only calendar settings and time
are retained.
Table 3. Installer Setup Menu. (CONTINUED)
58