CT1001/CT1002 Touchscreen Programmable Thermostat
1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2. FACTORY INSTALLED JUMPER.
3. OUTDOOR SENSOR REQUIRED IN SYSTEM W ITH FOSSIL FUEL BACKUP HEAT THAT IS NOT USING AN EXTERNAL FOSSIL FUEL
KIT.
4. OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE ON SELECT MODELS. W IRES MUST HAVE A CABLE
SEPARATE FROM THE THERMOSTAT CABLE.
5. MUST CONNECT THE 24VAC COMMON W HEN USING L. THE TERMINAL IS SHOW N AS EQUIPMENT MONITOR, CAN ALSO BE
USED AS A 24VAC OUTPUT. SEE HEAT PUMP SECTION ON PAGE 90.
6. "O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE INSTALLER SETUP.
Fig. 21. Typical hookup of multistage heat pump with auxiliary/backup heat
(3H/2C heat pump).
34
3
4
HEAT PUMP
S1 S2 C R RC W W2 Y2 Y G
S1 S2 C R RC E L Y2 Y G
O/B AUX
OUTDOOR/INDOOR
TEMPERATURE
SENSOR
2
R
C 1
CHANGEOVER
VALVE
FAN RELAY
OPTIONAL
24VAC
COMMON
CONNECTION
6
5
COMPRESSOR 2
EMERGENCY
HEAT RELAY
HEAT 2 RELAY
(AUXILIARY HEAT)
EQUIPMENT
MONITOR
COMPRESSOR 1