![Cortex CT1001 User Manual Download Page 57](http://html.mh-extra.com/html/cortex/ct1001/ct1001_user-manual_2669963057.webp)
CT1001/CT1002 Touchscreen Programmable Thermostat
Installer Setup
Name
Settings
Notes
Initial
Setting
Record
Humidifier Pad
Replacement
Reminder
0-humidifier pad replacement reminder off.
1-90 calendar days.
2-180 calendar days.
3-365 calendar days.
UV Lamp
Replacement
Reminder
0-UV lamp replacement reminder off.
1-365 calendar days.
Adaptive Intelligent
Recovery
1-Adaptive Intelligent Recovery control is
activated (system starts early so set-point is
reached by start of program period).
0-Conventional Recovery (system starts
recovery at programmed time).
Number of Periods
2-two periods available (Wake and Sleep)
4-four periods available (Wake, Day, Evening
and Sleep).
Not shown if non- programmable is
selected. 2 or 4 applies to all days
of the week. When it is changed the
schedule must be reprogrammed.
Minimum
Compressor
Off Time
5-five-minute compressor off-time setting
(factory setting).
0, 2, 3, 4-other compressor off-time settings.
Heat Temperature
Range Stop
40-90-temperature range (1°F increments) of
heating set-point.
Shown in 1/2 °C.
Cool Temperature
Range Stop
50-99-temperature range (1°F increments) of
cooling set-point.
Shown in 1/2 °C.
Table 3. Installer Setup Menu. (CONTINUED)