Description:
Manual L4 ES HP; L4 ES HP W
Document Number:
1004289
Created By:
MSHN
Revision Approval Date:
2019-06-28
Revision:
A
© Corroventa Avfuktning AB
26 (42)
Setup and maintenance menus
The setup and maintenance menus contain functions that
are not needed for normal operations.
Date and time:
Setting system date and system time: The
format is YY:MM:DD / HH:MM.
Language:
Language selection for the interface.
Menu system:
The menu system is set to Advanced as
standard with all functions visible and available. If it is set
to Basic, the more advanced functions are removed from
the menu system.
Press Create and wait while the machine establishes the
network. This can take up to one minute.
Once the network has been established, the display
switches between the slave units in the network menu.
These are indicated by type (e.g. L4 ES) and bus address
(e.g. 101).
To change the settings for a slave unit, press Change and
select the slave unit. The background lighting for the
selected unit starts to flash to confirm that the unit has
been selected.
Desired settings can also be made directly on the relevant
machine.
Start the master machine when all desired settings have
been made. The slaves start automatically within one
minute. The machines are stopped in the same way. Press
stop on the master machine and the slaves stop
automatically shortly afterwards.
As the network is controlled by the master machine, a
slave unit that is started manually is stopped when the
master machine is in standby. In the same way, a slave
unit that is stopped manually is restarted manually when
the master machine is in operation.