Description:
Manual L4 ES HP; L4 ES HP W
Document Number:
1004289
Created By:
MSHN
Revision Approval Date:
2019-06-28
Revision:
A
© Corroventa Avfuktning AB
20 (42)
Start view
When L4 ES starts up, two options appear for the user on
the display:
Start:
Starts the machine with standard settings,
continuous operation with maximum capacity. Previous
settings such as use of sensor control, timer etc.
Resume:
The machine resumes operation with the same
settings that previously applied.
If the user did not press the stop button before the power
was interrupted the last time the machine was used, the
machine will automatically resume operation when the
timer has counted down to zero.
The countdown can be stopped by pressing the Stop
button, which then switches the machines to standby
until it is started manually.
Normal start
Start after power cut –
automatic resumption of operation
Standard view
L4 ES must usually be switched off using the “Stop”
button below the display. The machine then switches to
post cooling mode, the fan and pump run for 120 seconds
before the machine switches off and excess condensation
water is pumped out.
When the machine is running in a control mode instead of
in manual mode, the setpoint (which is marked with black
background in the middle of the screen) can be increased
or decreased using the negative (-) and positive (+)
buttons.
Standard view graphics.