File : CS-SUP-MUTI-WTHERMAPP-E01.sxw
7.3.6 Set the day/night system parameters according to day of the week
The day/night system according to the day of the week parameter setting procedure is the same as that
described in the previous chapter with the exception that the “
Enable time window according to the day of the
week
” parameter is only set for days required.
For example, we wish to enable the time window from Monday to Wednesday.
The
'Enable time windows according to day of the week' parameter is set to
0x07.
In this way, the module wakes up during these time windows for a period set in the associated parameters
with a specific start time for each window from Monday to Wednesday.
For the other days of the week, the wake-up mode depends on the '
wake-up system status word
' :
'
Wake-up system status word
' = 0x01
the bit 1 is not enabled, thus the parameter 'Enable wake-up periods by day of week' is not
used ; so the rest of the week, the module uses the default wake-up period.
'Wake-up system status word
' = 0x03
the bit 1 is enabled, thus the parameter 'Enable wake-up periods by day of week' is used, so
the wake-up for the rest of the week will depend on this parameter.
Days with wake-up period enabled : default wake-up period
days with wake-up period disabled : periodic wake-up disabled (polling every 10 sec.)
The format of the applicatives commands for reading and writing internal parameters, is described in chapter
6.2.
WaveTherm modules – application handbook