background image

                                                                                                                                                                                               Tec hni c al  Ins truc ti ons

                                                                                            Oc t ober 19, 2007

C o r n i n g   C a b l e   S y s t e m s   G m b H   &   C o .   K G   ·   L e i p z i g e r   S t r .   1 2 1   ·   1 0 1 1 7   B e r l i n ,   G e r ma n y
T E L :   0 0 8 0 0 - 2 6 7 6 - 4 6 4 1   ( 0 0 8 0 0 - C O R N I N G 1 )   ·   F A X :   + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5   ·   E m a i l :   e me a . c s @ c o r n i n g . c o m
w w w . c o r n i n g . c o m/ c a b l e s y s t e ms

Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ 

products without prior notification. LANscape

is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. ©
2007 Corning Cable Systems. All rights reserved. Published in the EU.

Problem: Error light flashes

Possible Cause:

Solution:

1.  Ferrule Adapter maybe dirty

à

2.  The connector may be dirty

à

3.  The photo detector is dirty

à

4.  The connector is not loaded

correctly

à

5.  The ferrule adapter is not

properly secured in the adapter
port

à

6.  Weak Batteries

à

1.  Clean the Ferrule Adapter and connector. The adapter is

cleaned by the cleaning sticks provided in the tool.  Insert
stick into the adapter opening and rotate the stick 10 times,
clockwise (apply varying pressures to create a pumping
action). Don’

t reuse the stick.

2.  Clean the end face of the connector.

3.  Clean the photo detector with a dry wipe.

4.  Remove connector dust caps. The date code on the SC and

LC should be facing up.  The “UP” of the ST adapter should
be facing up.  The crimp tube must protrude past the crimp
arms.

5.  Make sure the proper ferrule adapter is being used and is

fully seated on the connector.

6.  Replace batteries

Photo
Detector

Reviews: