Maintaining the Pretium Tool
Problem: Power light does not come on or flashes
Possible Cause:
Solution:
1. The battery is low and needs to be
replaced
à
1. Replace the battery. If the light is still flashing
or not shining, please place an RMA
Problem: Cannot get a green light
Possible Cause:
Solution:
1. Cover not closed
à
2. Error Light not cleared
à
3. Fibre not inserted correctly in the
connector.
à
4. Bad Cleave
à
5. Broke fibre in the connector or defective
connector
à
6. Weak Batteries
à
1. Close lid before inserting the field fibre.
2. Check problem point “Power light does not
come on or flashes”
3. Hit reset button and repeat inserting field
Fibre in the connector and re- Cam.
4. Check chapter “Maintaining the Pretium
FBC-015 Cleaver”
5. Remove the connector and place another
one in the tool and retry
6. Replace batteries
If these maintaining instructions did not help solving the problem, please place a RMA