Filling the Barrels
Once the barrels have been BRIXed and purged, they may be filled with product. This is accomplished by going
to the Barrel Maintenance menu and pressing the FILL button. This starts the fill process for the highlighted
barrel. As the barrel fills, the barrel pressure sensor shuts off the barrel at a pressure of 28 psi. To completely fill
the barrel, open the relief valve on the faceplate of the barrel and allow some of the barrel pressure to escape.
This allows the barrel to continue filling. Repeat this process until the unit reaches the scribe mark indicated in
Figure 23. Once the product reaches the proper level, press the OFF button to stop filling the barrel. Press the
FREEZE button to start mixing and cooling the product and the CO
2
present in the barrel.
Calibrating a Motor
Motors are factory calibrated, but storage and transit can cause a shift in calibration. Calibration establishes a
new baseline for the motor assembly. This allows the system to determine proper viscosity settings for the motor.
As a part of installation, each barrel should be calibrated using the procedure in Table 18 and Table 19.
!
CAUTION
:
Calibration must be performed when the product in the barrel is completely liquid. There must not be any ice on
the scraper blade.
The Motor Setup Screen in Figure 24. allows you to select different motor types for each barrel in the unit and run
the calibration procedure on that motor. This procedure correlates the actual viscosity of the barrel and its
contents with the electrical characteristics of the motor. These characteristics are stored by the control system
and are accessed at the time of calibration for each particular motor.
Perform the procedure described in Table 18 to verify the motor type setting.
NOTE: If the Motor Type shown is “DEFAULT”, it indicates that the EEPROM is not installed or is
faulty.
Figure 24.. Motor Setup Screen
Relief
FCB Product Level
FUB Product Level
MOTOR
SETUP
12:51P
MAR 04
#1 MOTOR TYPE 1
#2 MOTOR TYPE 2
BACK CAL - +
Summary of Contents for VIPER 3 FLAVOR
Page 35: ......