Viper Installation Manual
© 2010-2016, Cornelius Inc.
- 19 -
Publication Number: 621360041TBINS
Refer to for Table 13. recommended settings based on syrup type.
To set all barrels in the system to the same viscosity setting, follow Table 10. and then press the ALL button at the
bottom of the display while highlighting the viscosity setting you desire for all the barrels.
VISC
SETUP
12:51P
MAR 04
#1 VISC RANGE 4 40-96
#2 VISC RANGE 5 44-103
BACK ALL - +
Figure 17.
When the viscosity settings are complete, press the BACK button to save the settings and return to the Select
menu, shown in Figure 12.
CO
2
Setup Menu
The CO
2
Setup menu, shown in Figure 18. allows the user to adjust the percentage of time that the CO
2
pulse
valves are open. This provides an adjustment of the overrun for the unit when using different syrups. The valves
use a one second interval duration time. Setting a valve to 45 activates the valve for 450 msec. out of each
second.
The CO
2
pulse valves may be set between 0 and 100%, in 5% increments. To change the settings of the CO
2
pulse valves, perform the procedure in Table 11.
BACK
ALL - +
CO2
SETUP
12:51P
MAR 04
#1 CO2 PULSE %: 45
#2 CO2 PULSE % 45
#3 CO2 PULSE % 45
Figure 18. CO
2
Pulse Valve Setup Screen
Table 10.
Step
Action
Procedure
1
Set viscosity range
From the Setup menu (Figure 12.), open the
Viscosity Setup menu, shown in Figure 17.
2
Select barrel
Use the up and down arrows to highlight the
desired barrel.
3
Set range
Use the + or - buttons at the bottom of the dis-
play to set the desired range.
4
Select barrel
Repeat Steps 2 and 3 for each barrel in the
machine.