Viper Installation Manual
Publication Number: 621360041TBINS
- 10 -
© 2010-2016, Cornelius Inc.
Figure 5. Cylinder CO
2
Connection
Syrup Requirements
NOTE: Syrup connections require 3/8” I.D. tubing. All hoses must reach the back of the unit plus
an adequate amount of extra tubing to allow the unit to be pulled out for servicing.
Syrup Connections
Use the appropriate fittings and clamps to connect the syrup line to the unit. Run the tubing for the syrup (3/8 in.
ID, Min.) from the backroom to the unit and make all appropriate connections. Do not turn on the syrup supply to
the unit.
FCB Unit
yl
p
p
u
S
2
O
C
BIB Syrup
BIB Syrup
BIB Pump
C
E
D
A
F
I
Water Filter
Connections
Tubing
1/2 Inch Beverage Tubing
3/8 Inch Beverage Tubing
1/4 Inch Beverage Tubing
3/8 Inch Tygon Tubing
A
B
C
D
E
F
1/2 Inch Hose Barb to 3/4 NPT
1/4 Inch Female Flare Nut and Barb (1/4)
Direct Connection to Syrup
Outlet on Syrup Pump
Direct Connection to CO2
Inlet on Syrup Pump
Direct Connection to Syrup
Inlet on Syrup Pump
1/2 to 3/8 Inch Fitting Reducer
W
ater Inlet
Syrup Line 1
Syrup Line 2
CO2 Inlet
BIB Syrup
BIB Syrup
BIB Pump
C
E
D
G
BIB Pump
C
E
D
BIB Pump
C
E
D
Syrup Line 3
Syrup Line 4
G
¼ Inch Cross Barb
K
H
J
H
CO2 Regulator
I
3/8 Inch TEE Barb
J
3/8 Inch Flare Nut and Barb (3/8)
K
3/8 to 1/4 Inch Fitting Reducer
H
H
B
Max 3 F
eet
J
K
K
K
K
F
3 F
eet Typical
115 Psig
75 Psig
75 Psig