background image

 Operator’s Manual                                   

Publication Number: 620047630OPR

- 12 -

© 2009, IMI Cornelius Inc.

WARRANTY

IMI CORNELIUS Inc., ("CORNELIUS") does warrant to the original purchaser from CORNELIUS who buys solely 
for commercial or industrial uses, or for resale in the ordinary course of business, that each of the Products 
covered by this Commercial Warranty shall be free from defects in material and/or workmanship, under normal 
and proper use and service conditions.

Any products covered by this Commercial Warranty (including components thereof demonstrated to have been 
defective when shipped by CORNELIUS will be either repaired, replaced (with new or rebuilt replacement) or the 
purchase price therefor refunded, as CORNELIUS may determine solely in its discretion. A Product or 
component thereof covered by this Commercial Warranty supplied as a Warranty Replacement will assume the 
balance of the Period of Warranty applicable to the original measured from the date of replacement. This 
Commercial Warranty does not include, and CORNELIUS will not assume or pay, the expense of travel time or 
mileage, any premium time of any party other than CORNELIUS; any repair, replacement, analysis or any other 
services or parts furnished by any party other than CORNELIUS unless specifically authorized in advance and in 
writing by CORNELIUS. This Commercial Warranty does not include labor for diagnosis, removal or installation of 
any products or components.

Products covered by this Commercial Warranty include all beverage and food dispensing or vending equipment 
manufactured or sold by CORNELIUS after the date hereof (not excluded hereinafter) and this Commercial 
Warranty is further limited to the use of that equipment in connection with soft drinks, soft drink syrups, beer, 
coffee, hot chocolate, tea or food commodities for which use the particular product has been identified by 
CORNELIUS.

Specific exclusions to this Commercial Warranty are OEM Sales, water filter cartridges, coin mechanisms, light 
bulbs, fuses, glass, diaphragms, seals, o-rings, silicone or rubber parts, refrigeration access valves or related 
refrigeration leaks, parts in contact with water or the product dispensed and which become inoperative due to 
scale or chemical change, normal maintenance items. This Commercial Warranty shall not apply to damage 
resulting from improper voltage, inadequate wiring, abuse, accident, alteration, misuse, neglect, unauthorized 
repair, improper cleaning or failure to follow installation, operating or maintenance instructions. Remote 
watercooled refrigeration systems must have properly sized and installed remote cooling towers or systems. 
Failure of refrigeration components (compressor-valves) due to remote condenser system failure, incorrect 
sizing, operation, or installation are not covered by this Commercial Warranty.

The Period of Warranty is (i) one (1) year from the date of installation, or, (ii) fifteen (15) months from the date of 
shipment by CORNELIUS of a product covered hereby, whichever time period elapses first. For products 
incorporating a refrigeration system the Period of Warranty, with respect to the refrigeration system only (defined 
as the compressor, evaporator, condenser, and interconnecting tubing [not to include any access valves]), is five 
(5) years from the date of installation or sixty-three (63) months from the date of shipment by CORNELIUS, 
whichever time period elapses first.

Any claim under this Commercial Warranty must be made as promptly as is reasonably possible, but in no event 
later than sixty (60) consecutive calendar days, after the discovery of the defect. Such claims are to be directed to 
the CORNELIUS SERVICE DEPARTMENT at 101 Broadway Street West, Osseo, MN 55369 (763) 488-8200.

Under no circumstances should the entire unit be returned to CORNELIUS except for repair or replacement of the 
sealed refrigeration unit. Whenever a product is returned to CORNELIUS for repair or replacement of the sealed 
refrigeration system under the terms of the Commercial Warranty and the defect is found to exist in parts other 
than the sealed refrigeration system (example: ice bank control, agitator motor, condenser fan motor, start 
capacitor or relay), an evaluation fee of twenty-five dollars ($25.00) may be charged. If such defective part needs 
replacement or repair and is within its Period of Warranty, such part will be replaced or repaired at no charge, 
except for labor for removal and installation of such part which will be the responsibility of the customer. If not 
within its Period of Warranty, a charge for such part and the labor will be made.

The product covered by this Commercial Warranty, or components thereof, must not be returned to CORNELIUS 
without authorization from the CORNELIUS SERVICE DEPARTMENT. Instructions for return will be given with 
any such authorization. All returned products and/or parts must be shipped prepaid to CORNELIUS. Return 
shipping costs of repaired or replacement products or parts will be prepaid by CORNELIUS, except that as to 
original purchasers in Alaska or Hawaii, CORNELIUS will pay shipping costs only to Seattle or San Francisco 

Summary of Contents for JetSpray JS7C

Page 1: ...JetSpray Visual Display Dispenser JS7C Operator s Manual Release Date July 9 2009 Publication Number 620047630OPR Revision Date November 23 2009 Revision B...

Page 2: ...have been trained and are skilled in working with electrical plumbing pneumatic and mechanical equipment Appropriate safety precautions should be followed and all local safety and construction requir...

Page 3: ...Your JS7C 4 Cleaning the Dispenser 4 To Assemble 4 Operating Procedures 6 Frequent Maintenance Procedures 7 Cleaning the Bowls 7 Cleaning the Condensate Drains 7 Sanitizing the Unit 7 Ventilation 8 C...

Page 4: ......

Page 5: ...ch if not avoided WILL result in serious injury death or equipment damage Warning WARNING Indicates a potentially hazardous situation which if not avoided COULD result in serious injury death or equip...

Page 6: ...nvironment will cause residual sanitizing solution or water remaining inside the Unit to freeze resulting in damage to the internal components LOCATION Place the dispenser on a solid level surface wit...

Page 7: ...ordance with Federal State and Local codes It is the operator s responsibility to ensure that the potable water supply is available NOTE JetSpray dispensers conform to the requirements of the Model Wa...

Page 8: ...Grasp the clips on the handle Squeeze clips until they are free from the panel Pull straight down on the handle 2 Disassemble the bowl lid gasket and pump housing assemblies CAUTION Abrasive cleaners...

Page 9: ...not to wrinkle the gasket If gasket is wrinkled beverage will leak out of bowl See Figure 4 Figure 4 6 Locate the blade in the bowl The magnet self locates the blade once it is moved into position Ma...

Page 10: ...e is free of wrinkles and extends below the support spout about a 1 4 inch See Figure 7 Figure 7 Operating Procedures 1 Follow beverage manufacturer s directions in filling bowls To aid in filling the...

Page 11: ...DENSATE DRAINS 1 To remove the condensation drains push in on the front panel just under the drain and pull down with fingers as shown in Figure 8 Figure 8 2 To replace the condensate drains hold the...

Page 12: ...re replacing it 5 Replace back panel placing top edge up under condensate tray and pushing it in at the bottom 6 Reinstall the back panel screws 7 Plug the power cord into the wall socket CLEANING THE...

Page 13: ...ROWN 115V BLACK 230 V BROWN 115V BLACK POWER CORD PLUG GROUND GREEN YELLOW L THERMOSTAT OVERLOAD COMPRESSOR B CLOSES ON RISE IN TEMPERATURE 50 HZ UNIT ONLY START CAP COND FAN CIRCUIT MOTOR MOTOR AGITA...

Page 14: ...ns 11 4 liters Over 5 US gallons 19 liters Refrigeration JetSpray 1 6 h p Hermetically Sealed System Refrigerant R134a Refrigerant 3 49 ounces 99 grams Spray Drive and Fan Motor No Oiling Required Pow...

Page 15: ...Operator s Manual 2009 IMI Cornelius Inc 11 Publication Number 620047630OPR Environment Temperature Operating 60oF 16oC to 110oF 43oC Storage Above 20o F 7o C with bowl empty and dry Humidity Below 95...

Page 16: ...e to follow installation operating or maintenance instructions Remote watercooled refrigeration systems must have properly sized and installed remote cooling towers or systems Failure of refrigeration...

Page 17: ...PECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER WHETHER ANY CLAIM FOR RECOVERY IS BASED ON THEORIES OF CONTRACT NEGLIGENCE OR TORT Without limitation these liabilities do not include...

Page 18: ...Operator s Manual Publication Number 620047630OPR 14 2009 IMI Cornelius Inc...

Page 19: ......

Page 20: ...IMI Cornelius Inc www cornelius com...

Reviews: