![Cornelius IRC1030 Installation Manual Download Page 9](http://html1.mh-extra.com/html/cornelius/irc1030/irc1030_installation-manual_2668208009.webp)
vii
166240001
ICE CUBER SPECIFICATION – 60 HERTZ
MODEL
IRC630
IRC830
IRC1030
IRC1030L
IRC1230
UNIT
Volts
230
230
230
230
Phase
1
1
1
1
Hertz
60
60
60
60
No. Wires
2+ground
2+ground
2+ground
2+ground
MIN. CIRCUIT
Amps
20
20
20
20
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps
20
20
20
20
REFRIGERANT
Type
R404a(HP62)
R404a(HP62)
R404a(HP62)
R404a(HP62)
Weight (oz)
170
170
210
210
Weight (g)
4820
4820
5954
5954
COMPRESSOR
Volts
230
230
230
230
Phase
1
1
1
1
Hertz
60
60
60
60
LRA
69
61
82
96
RLA
8.8
12.5
13.0
13.5
CONDENSER FAN MOTOR (AIR COOLED SYSTEMS ONLY
AIR CIRCULATION FAN MOTOR (WATER-COOLED & REMOTE SYSTEMS ONLY)
Volts
230
230
230
230
Phase
1
1
1
1
Hertz
60
60
60
60
Amps Running
0.36
0.36
0.36
0.36
Watts
6
6
6W
6
WATER PUMP
Volts
230
230
230
230
Phase
1
1
1
1
Hertz
60
60
60
60
Amps Running
0.5
0.5
0.5
0.5
HP
1/30
1/30
1/30
1/30
Summary of Contents for IRC1030