166240001
ICE CUBER SPECIFICATION – 60 HERTZ
MODEL
IRC1448
IRC1448-3PH
IRC2448
IRC2448-3PH
UNIT
Volts
230
230
230
230
Phase
1
3
1
3
Hertz
60
60
60
60
No. Wires
2+ground
3+ground
2+ground
3+ground
MIN. CIRCUIT
Amps
25
25
30
25
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps
25
25
30
25
REFRIGERANT
Type
R404a(HP 62)
R404a(HP 62)
R404a(HP 62)
R404a(HP 62)
Weight (oz)
250
250
320
320
Weight (g)
7088
7088
9072
9072
COMPRESSOR
Volts
230
230
230
230
Phase
1
3
1
3
Hertz
60
60
60
60
LRA
95.6
82
125
90
RLA
23.9
10
20
13
CONDENSER FAN MOTOR (AIR COOLED SYSTEMS ONLY
AIR CIRCULATION FAN MOTOR (WATER-COOLED & REMOTE SYSTEMS ONLY)
Volts
230
230
230
230
Phase
1
1
1
1
Hertz
60
60
60
60
Amps Running
0.36
0.36
Watts
6
6W
WATER PUMP
Volts
230
230
230
230
Phase
1
1
1
1
Hertz
60
60
60
60
Amps Running
0.5
0.5
0.77
0.77
HP
1/30
1/30
1/50
1/50