![Cornelius IRC1030 Installation Manual Download Page 11](http://html1.mh-extra.com/html/cornelius/irc1030/irc1030_installation-manual_2668208011.webp)
ix
166240001
ICE CUBER SPECIFICATION – 50 HERTZ
MODEL
IRC630E50
IRC630E50L
IRC830E50
IRC830E50L
IRC1030E50
IRC1030E50L
IRC1230E50
IRC1230E50L
UNIT
Volts
220
220
220
220
Phase
1
1
1
1
Hertz
50
50
50
50
No. Wires
2+ground
2+ground
2+ground
2+ground
MIN. CIRCUIT
Amps
20
20
20
25
MAX FUSE SIZE (HVAC CIRCUIT BREAKER REQUIRED)
Amps
20
20
20
25
REFRIGERANT
Type
R404a(HP62)
R404a(HP62)
R404a(HP62)
R404a(HP62)
Weight (oz)
170
170
210
250
Weight (g)
4820
4820
4820
4820
COMPRESSOR
Volts
220
220
220
220
Phase
1
1
1
1
Hertz
50
50
50
50
LRA
53
58
64
75.9
RLA
8
12
12.5
13
CONDENSER FAN MOTOR (AIR COOLED SYSTEMS ONLY
AIR CIRCULATION FAN MOTOR (WATER-COOLED & REMOTE SYSTEMS ONLY)
Volts
220
220
220
220
Phase
1
1
1
1
Hertz
50
50
50
50
Amps Running
0.3
0.3
0.3
0.3
Watts
6
6
6
6
WATER PUMP
Volts
220
220
220
220
Phase
1
1
1
1
Hertz
50
50
50
50
Amps Running
0.5
0.5
0.5
0.5
HP
1/30
1/30
1/30
1/30
Summary of Contents for IRC1030