5. Remove any excess sealant.

Note: For non-electrical valves, skip the next step.

6. Mount the Transformer power supply under the counter, in a position to allow access to the electrical outlet

and to allow the 24V power cord to reach the dispenser.

7. Install the drain hose to the ice bin drain fitting and route the drain hose to a permanent drain.

Free-Standing Dispenser

1. Install the 6“ legs to the dispenser cabinet if they are to be used.

2. Place the dispenser in the location selected. Be sure the dispenser is level. This is important to ensure that

the bin drains properly.

3. Mount the Transformer power supply in a convenient location to allow access to the electrical outlet and to

allow the 24V power cord to reach the dispenser.

4. Install the drain hose to the ice bin drain fitting and route the drain hose to a permanent drain.

SANITIZING PRODUCT COLD PLATE TUBING

Preparing the Cleaning Solution: 

Using a clean tank (tank system) or a five-gallon container (bag-in-box sys-

tem), prepare a full tank or container of liquid dishwasher detergent by using 70

°

F (21

°

C) to 100

°

F (38

°

 C)

potable water and 0.5 oz. (15 ml) of liquid dishwasher detergent (such as Joy, Ivory, etc.) to one gallon of pota-
ble water. Shake detergent solution to thoroughly  mix the solution.

Preparing the Sanitizing Solution: 

 Using a clean tank (tanks system) or a five-gallon container (bag-in-box

system), prepare sanitizing solution using 70

°

F (21

°

C) to100

°

F (38

°

 C) potable water and 0.5 oz. (15 ml) of

household liquid bleach such as non-scented Hi-Lex or Chlorox that contains a 5.25 % sodium hypochlorite con-
centration to one gallon of potable water.This mixture 

must not

 exceed 200 PPM of chlorine. Shake sanitizing

solution to thoroughly mix.

STEP 1. WASH PRODUCT/SYRUP SYSTEMS

1. Using a clean tank (tank system) or a five-gallon container (bag-in-box system), prepare a full tank or con-

tainer of liquid dishwasher detergent by using 70

°

F (21

°

C) to 100

°

F (38

°

 C) potable water and 0.5 oz. (15

ml) of liquid dishwasher detergent (such as Joy, Ivory, etc.) to one gallon of potable water. Shake detergent
solution to thoroughly  mix the solution.

Tank Systems.

A.

Observe and note CO

2

 pressure setting on the tanks CO

regulator, then re-adjust CO

regulator to 60

to 80-psi. Pressurize the tank containing detergent solution to 60 to 80-psi.

B.

Connect detergent solution tank, pressurized at 60 to 80-psi, into one of the tubing systems.

        Bag-in Box Systems.

C.

Install bag valves (cut from empty bag-in-box syrup containers) on ends of syrup containers syrup out-
let tubes connectors.

D.

Place all syrup outlet tubes, with bag valves on their ends, in container containing detergent solution.

2. Flush the syrup system and dispensing valve as follows:

A.

Place waste container under applicable dispensing valve.

B.

Activate the dispensing valve for one minute to purge all syrup and flush out the syrup system.

Summary of Contents for Drop-In and Free-Standing Ice Cooled Dispensers

Page 1: ...oute and connect unit ice bin and drip tray drain hoses All drains and connections to such drains must meet local plumbing codes Units with electrically operated valves must be located near a properly...

Page 2: ...g Solution Using a clean tank tanks system or a five gallon container bag in box system prepare sanitizing solution using 70 F 21 C to100 F 38 C potable water and 0 5 oz 15 ml of household liquid blea...

Page 3: ...p systems and flush detergent solution out of syrup sys tems as instructed in step A preceding 4 Remove potable water source from the syrup system STEP 3 SANITIZE COOLING SYSTEMS 1 Using a clean tank...

Page 4: ...FF then ON for 15 seconds Repeat ON and OFF cycles for 15 cycles 3 Repeat preceding steps to purge sanitizing solution out of the remaining syrup systems and dispensing valves 4 Remove potable water s...

Page 5: ...nits must have a pre mix supply connected to each inlet for each valve to be supplied Refer to the plumbing diagram for details of the hook up Note A plumbing diagram when supplied with the unit can b...

Page 6: ...I CORNELIUS INC MASON CITY IA DRINK DISPENSERS VALVE TYPE MANUFACTURER PORTION CONTROL MAXIMUM OPERATING PRESSURE CORNELIUS 130 psi LANCER 100psi FLOWMATIC 100psi McCANN 130psi PUSH BUTTON CORNELIUS 1...

Page 7: ...ensing valve syrup flow regulator G Tapered nylon washer inside tube swivel nut connector distorted from being overtightened G Replace nylon washer and make sure it seats properly ADJUSTMENT OF DISPEN...

Page 8: ...ion E Warm Product No ice in bin bridged ice on cold plate or plugged drain E Replenish ice break ice up to eliminate bridging unplug the drain NOTE If water supply is dirty be sure to flush lines and...

Page 9: ...nes restricted G Sanitize syrup system as instructed ONLY SYRUP DISPENSED A Plain water inlet supply line shutoff valve closed A Open plain water inlet supply line shutoff valve B Carbonator power cor...

Reviews: