3
630460050SER
SPECIFICATIONS
Model
Cond.
Unit
VAC
Hz.
Ph.
Wire
Comp.
RLA
Fan
Amps
GrmtrA
mps
Refrig.
Oz. Type
Circuit
Fuse
CMP600–30A
Air Cooled
115
60
1
2
12
1
2
28 R404A
20
INSTALLATION INSTRUCTIONS
1. REMOVE ICEMAKER FROM CARTON:
A.
Keep unit in the upright position, remove carton and pallet from unit and inspect unit for damage.
Upon inspection of unit, if any damage is found, file a claim with carrier immediately.
B.
Locate Startup Card either on outside of container or on plastic liner. Fill in proper information and
send one copy to factory, and other copy to Distributor. Postage is prepaid.
2. PREPARATION OF INSTALLATION SITE:
A.
The refrigeration system on air cooled units requires airflow, so a well ventilated area should be
chosen. A minimum of (6) inches must be maintained, free of any obstruction, for air intake. A
minimum of (4) inches clearance is required for air exhaust.
3. WATER INLET HOOK–UP:
A.
Water Inlet – Fitting is a 1/4” SAE male flare located at the left rear bottom of the unit. Connect water
supply with a 1/4”or larger copper or flexible tubing.
B.
Water Pressure – Unless otherwise specified, the unit is designed to operate on water pressures
between 10 P.S.I. and 90 P.S.I. (NOTE: for pressures above 90 P.S.I. a regulator must be installed).
C.
Water Cooled Condensers
a.
Inlet to modulating valve uses 3/8” FPT. Use separate 3/8” or larger water line.
b.
Outlet is 3/8” FPT.
D.
Filters – Filter/Conditioners are recommended on supply lines to icemakers. Never run the water
supply to water cooled Condenser through Filter/Conditioner, it uses up the cartridge unnecessarily
and a saturated cartridge can starve the icemaker causing premature component damage. Separate
water supplies are recommended.
NOTE: Unit must be installed per local plumbing code.
4. ELECTRICAL SUPPLY:
A.
Power Access – Is provided by way of a 7/8” dia. hole in the base. Route incoming power in conduit,
to icemaker electrical control box.
B.
Make connections to wires provided in control box and ground lug/screw. Plug unused hole.
C.
Fused Line – Should be a dedicated circuit checked and sized according to electrical rating shown on
unit nameplate.
NOTE:
Unit must be installed per local electrical code.
5. DRAIN CONNECTION:
A.
Bin Drain– is a ” ID flexible tube located at the left bottom rear of the unit. Extend this line to proper
drain.
B.
Overflow Line– is a 3/8” ID flexible tube located at the left bottom rear of the unit. Extend this line to
proper drain.
6. AUGER ENGAGEMENT:
Be certain that auger is fully engaged to lower drive and that extruding head is fully engaged to evaporator.
7. INITIAL START UP, CHECKS & ADJUSTMENT INSTRUCTIONS:
NOTE:
Do not start unit before completing Installation steps 1–6.