![Cornelius CMP600-30A Service Manual Download Page 15](http://html1.mh-extra.com/html/cornelius/cmp600-30a/cmp600-30a_service-manual_2668158015.webp)
12
630460050SER
TROUBLESHOOTING
IMPORTANT: Only qualified personnel should service internal components or electrical wiring.
TROUBLESHOOTING GEAR MOTORS
Basically, Gear motor problems can be narrowed down to three areas of checkout.
THE GEARMOTOR WILL NOT RUN
1. No voltage to the transmission terminals – check external circuit.
2. Low voltage – check supply.
3. Problems in the gear motor electrical circuit. See Figure 5
THE GEARMOTOR STARTS BUTS TRIPS REPEATEDLY ON THE
OVERLOAD PROTECTOR:
1. Voltage – high or low voltage can cause the overload to trip.
2. High Gear motor amperage draw, see Specification Chart for ratings and Troubleshooting Guide.
FIGURE 5. OUTPUT SHAFT
THE MOTOR RUNS BUT OUTPUT SHAFT DOES NOT ROTATE:
1. Replace defective gear motor.
CAUTION: Be sure unit is disconnected from the power source. Disconnect the
transmission cable.