Trouble
Probable Cause
Corrective Action
Not enough ice in the cup.
A. Ice bin empty.
B. Defective gate cylinder.
C. CO2 supply disconnected or
depleted.
D. Agitator motor defective or wired
incorrectly.
Fill ice bin.
Call for service.
Reconnect CO2.
Replace CO2 cylinder.
Call for refill (bulk)
Call for service
Call for service.
Ice will not dispense.
A. Ice bin empty.
B. Defective gate cylinder.
C. CO2 supply disconnected or
depleted.
D. Agitator motor defective or wired
incorrectly.
Fill ice bin.
Call for service.
Reconnect CO2.
Replace CO2 cylinder.
Call for refill (bulk)
Call for service
Call for service.
Drinks too foamy.
A. Carobonator pressure too high.
Normal operating range should be
80 - 100 P.S.I.
Call for service.
Won’t pour drinks.
A. Cup tubes empty.
Refill cup tubes with correct
cups.
Troubleshooting – Trouble/Probable Cause Chart