Commissioning/shutdown
Cornelius Deutschland GmbH
Document no. TD0004100
Version 01/07/2019, Index 1
Installation and service manual Tower
Nueva Style
26
8
Commissioning/shutdown
DANGER!
Risk of personal injury and equipment damage due to non-compliance with safety information!
Failure to observe the safety information will result in a risk of bringing about operating conditions at the unit,
which may cause personal injury or equipment damage.
•
Please always strictly observe all safety measures and information/instructions; see chapter 1.
NOTICE!
All installation, maintenance and repair work at the unit is to be carried out by an expert only.
WARNING!
Risk of personal injury and equipment damage due to operation by non-qualified staff!
It is dangerous for non-qualified staff to operate the unit!
•
Service operations on this unit may only be carried out by trained and certified experts who have been
trained in carrying out service operations on this unit.
•
All wiring and plumbing must be carried out in compliance with national and local laws, regulations and
guidelines. Non-compliance with these laws, regulations and guidelines may result in death, serious injury
or equipment damage.
8.1
Commissioning
NOTICE!
The following describes how the unit is put back into service by an expert following a longer shutdown period
(> 24 hours).
If the unit is to be put back into operation after a temporary shutdown (< 24 hours), this may be carried out by
the operator or user; see the document “Tower operator manual”, document no. TD0004000.
NOTICE!
Maximum operating pressure of the valves is 100 PSI (689.48 kPa).
Prerequisites
References
The undercounter cooler has been put into service.
See the document “Undercounter cooler installation and ser-
vice manual”.
The unit has been installed correctly.
see chapter 5.3
The unit has been connected to the mains supply.
see chapter 5.3
Required tools/materials
ID/reference
Qty/amount
Comment
Undercounter cooler installation and
service manual
Document no.
Various
1
Operator manual
Undercounter cooler
Document no.
Various
1
Operator manual
Tower
Document no.
TD0004000
1
1. Turn the key switch (Fig. 55/1) to position “I”.
The unit will power up.
If the unit does not power up, see chapter 9.
2. Clean the tubes and valves; see chapter 6.2.
3. Clean the outside of the unit; see the document “Tower operator manual”, document no.
TD0004000.
4. If applicable, carry out the configuration settings for the dispensing valves; see dispensing
valve documentation.
Fig. 55
1