Use and Maintenance Manual – 09/2016 Rel. 0
Page 17
14.2 Machine calibration for the TRUCK wheel type
The calibration for the TRUCK wheel type is unique.
To perform machine calibration, you must first provide for the following material:
•
A balanced wheel with steel rim that has the following dimensions: Diameter 22.5”. It is not possible to use wheels with
aluminum rims;
•
A 300 grams weight.
To perform machine calibration, proceed as follows:
Phase
Description
1
Switch on the machine.
2
Press the [F+P3] button
. The display
will show the message in the picture on the left (this indicates
that we have entered Service mode).
3
Press the [P3] button
. The message in the picture on
the left will be shown on the display (machine calibration for
TRUCK wheels).
4
Remove the wheel and any other accessories from the shaft.
5
Press the [P3] button
. The display will show the
message in the picture on the left.
6
Press [P8] key Start
. The machine will run a launch.
7
At the end of the launch the display will show the message in
the picture on the left.
8
Mount the wheel on the shaft and enter the wheel dimensions
by pressing the [P1]
, [P2]
, [P3]
to select the dimensions to change, and the [P4]
or
[P5]
to edit the value. If the dimensions of the
wheel have been entered before accessing the calibration
program, this step can be skipped.
Press [P8] key Start
. The machine will run a launch.
9
At the end of the spinning, the inverter brake stops the wheel
in the position as indicated in the left display showing the value
300.