9.5.
Periodic maintenance
All inspections must be done with the machine switched off.
Although the intervals between these inspections depend on the frequency of use of the
brake, they should be done every 3 months in any case so as not to compromise all
aspects of safety.
1.
Using a feeler gauge, check that the play between the disc and each brake lining is 1 mm
(Photo 44). If the play encountered is greater, reset the original play as described in section
9.1.
Photo 44
2.
There is a wear line on the brake lining, however, it is advisable to check that the wear of each
lining does not exceed 9 mm in order not to compromise the correct operation and good
working condition of the brake. When the lining pads reach maximum wear replace them as
described in section 9.2.
3.
Check that the surfaces of the brake linings and the disc are not contaminated with grease,
oil or similar substances which prevent the brake from working efficiently.
4.
Check that the cup springs are lubricated well.
5.
Check that the anchor screws of the brake have been tightened correctly.
6.
Check that the hoses are undamaged.
7.
Apply the brake repeatedly to check that the gaskets are undamaged and the springs are
working correctly.
2 mm
1 mm