-Press

 

[Chrono] button choose P1, P2, P3 programs.

For programming see paragraph 10.1

ECO Mode

This mode lowers the set temperature of 3°C regardless of other 
radiator settings.

To  activate  /  deactivate  the  function,  press  the  dedicated  [ECO]  

button.

 

(See paragraph 10.1)

Timer-2H Mode 

Press the [mode] button until the displays shows the "2h".

The device is active at maximum power for 2 hours, up to a limit 
temperature of 32°C. “Boost” mode automatically interrupts, after 2 hours 
the thermostat goes back to the operating mode previously set.

the user can select other modes at any time, by pressing [Mode] botton.

.

Key Lock

It is possible to lock the devide to the "On / Stand-by" button to avoid 
improper or involuntary use, such as protecting children or in a public 
space.

To turn on/off the keypad, press the [mode] button for 5 seconds

.

Adaptive Starting Control ASC*

This function, if activated, will turn on the radiator in advance of the 
programmed (Max 2 hours) to ensure that the room has reached the 
desired temperature at the set time.
NOTES: The function takes at least a couple of days to reach 

maximum efficiency.

Open Window Detection function *

The "Open Window Detection" function enables detecting of an open 
window by sensig a sudden decrease of the temperature in the room. 
In such a case, the device deactivates the heating element for a 
maximum of 30 minutes until at which point radiator will resume to 
operate in the previously set state.
When the function is enabled, the window symbol on the display is 
ON.
When the function is enabled and the window opening is detected, 

the icon  

  on the display flashes.

* To activate the functions, refer to paragraph 10.1

a) Set date and time

• Activate  "Stand-by"  mode  and  press  the  [chrono]  button  for  more 

than 5 seconds.

•  With  the  [+]  and  [-]  buttons,  scroll  through  the  menu  to  the  Time 
function, press [mode] to confirm.
• Day: The word "day"  blinks for 2 seconds, with the [+] and [-] buttons 
select the Day and confirm with the [mode] button.
• Time: Use the [+] and [-] buttons to select the time and confirm with 
the [mode] button.
• Minute: Use the [+] and [-] buttons to select the minutes and confirm 
with  the  [mode]  button.  When  finished,  the  thermostat  will  exit  the 

programming menu. 

b) Set programs for the Chrono mode (P1,P2,P3):

•  Activate  the  "Chrono"  mode  using  the  [mode]  button  press  the 
[Chrono] button to choose wich of the programs P1, P2, P3 to set.
• Hold the [Chrono] button to set the time sequence.

Now a time sequence can be set for each day of the week. It starts with 
day 1, the time zone is displayed, the desired sequence is selected 

with  the  [+]  and  [-]  buttons  to  select,  for  each  hour,  the  "Comfort" 
temperature (full bar) button [+] and the temperature "Night" (empty 
bar) button [-].
Press  [Mode]  to  confirm  the  first  day  setting,  repeat  the  same 

procedure for the remaining 6 days of the week; the day setting is 

saved and it can be copied to the next day by pressing [Mode] button.

c) Enabling “Open window detection”, “ASC”, “wireless” “ECO” 
functions;

a. The user can enable or disable these functions as follows:
b. Set the radiator to stand-by mode.

c. Press [chrono] key for more than 5 seconds.
d. With [+] and [-] keys, scroll the menu until “Func” function, press 
[mode] key to confirm.
e. Press [+] or [-] keys to enable or disable the open window detection 

function.

f. Press [mode] key to go to the selection of “ASC” function.
g. Press [+] or [-] keys to enable or disable the function.
h. Press [mode] key to go to the selection of “ECO” function.
i. Press [+] or [-] keys to enable or disable the function.

j. Press mode key again to go back to “Stand-by” mode.

Consumption indicator

 

 

 

N.B.  When the " 

 " is on, the heating element is active.

Max consumption: inticates the appliance
use maximum energy available

Medium consumption: it is advisable 
to save energy consumption by reduce 
temperatures setting.

Low consumption: the radiator is set 
optimally

Summary of Contents for Ardesia

Page 1: ...o radiatori elettrici con Termostato Ambiente Digitale Operating instructions electric radiators with Digital Thermostat Bedienungsanleitung Elektrische Heizkörper mit Digitalem Raumthermostat Instrucciones de uso Radiadores eléctricos con Termostato Ambiente Digital Models Ardesia ...

Page 2: ... 2 Cod 1910000000078 nv00 ...

Page 3: ...Termostato ambiente digitale pag 4 EN Operating instructions electric radiators with digital thermostat pag 9 DE Betriebsanleitung Elektrische Heizkörper mit digitalem Raumthermostat pag 14 ES Instrucciones de uso Radiadores eléctricos con termostato ambiente digital pag 19 Index ...

Page 4: ...ni riportate di seguito Il radiatore non abbia subito danneggiamenti durante il trasporto le movimentazioni o l installazione e non sia stata effettuata alcuna riparazione e o manomissione non espressamente autorizzata da parte di terzi Il materiale sia stato immagazzinato in buone condizioni e al riparo dalle intemperie prima di essere installato L installazione del prodotto deve essere effettuat...

Page 5: ...re la resistenza l operazione può essere effettuata unicamente da parte del costruttore da un suo delegato o da una persona con qualifica similare in modo da prevenire ogni rischio 10 Istruzioni termostato Display LCD Display LCD a Modalità ON STAND BY Premere il tasto per accendere l apparecchio o attivare la modalità Stand by In modalità ON il display mostra la Modalità la Temperatura corrente D...

Page 6: ... raggiunga la temperatura desiderata all ora impostata Note la funzione richiede almeno un paio di giorni di attivazione per avere la massima efficienza Funzione Rilevamento finestra aperta Il radiatore è in grado di individuare se è stata aperta una finestra mediante la rilevazione di un rapido calo della temperatura ambiente Se ciò succede il radiatore si spegne per 30 minuti al temine dei quali...

Page 7: ...Directive 2014 35 UE Directive 2014 30 UE Directive 2012 19 UE Directive 2009 125 EC Directive 2011 65 UE Règlement EU 2015 1188 Morro D Oro lì 03 12 2018 11 Smaltimento Al termine della vita questo apparecchio deve essere depositato negli appositi centri di raccolta per il suo riciclaggio non è un rifiuto domestico ordinario In caso di sostituzione può essere inviato al vostro distributore Gestir...

Page 8: ... della temperatura ambiente tramite termostato meccanico No Consumo ausiliario di energia elettrica Con controllo elettronico della temperatura ambiente No Alla potenza termica nominale elmax 0 4 0 5 0 75 0 9 1 1 2 1 5 2 0 KW Con controllo elettronico della temperatura ambiente e temporizzatore giornaliero No Alla potenza termica minima elmin n d KW Con controllo elettronico della temperatura ambi...

Page 9: ...y a third party if not expressively authorized The material has been stored in good condi tion and protected from the weather before being installed The installation of this product should be performed by qualified personnel and in accordance with these instructions and all system and safety rules both national and local Do not place the radiators in rooms with the presence of chlorine va pours or...

Page 10: ...hrono Mode In this mode the ambient temperature is maintained at the comfort level or at the Nightly level according to time slots programmed as desired by the user Press the mode button until the corresponding icon appears on the English Crono Key Key Lcd display Mode Key Key Eco Key On Stand by Key complete with a pre mounted Shuko plug Before connecting up make sure that the rated voltage of th...

Page 11: ...h the and buttons scroll through the menu to the Time function press mode to confirm Day The word day blinks for 2 seconds with the and buttons select the Day and confirm with the mode button Time Use the and buttons to select the time and confirm with the mode button Minute Use the and buttons to select the minutes and confirm with the mode button When finished the thermostat will exit the progra...

Page 12: ...d ance with Directive 2002 95 EC DECLARATION OF CONFORMITY The Company Cordivari S r l with registered office in Morro D Oro TE Zona Industriale Pagliare hereby declares under its own responsibility that the household electric radiators listed in par 1 comply with following rules EN 60335 1 2012 EN 60335 2 43 2005 A1 2006 A2 2009 EN 55014 1 2008 EN 55014 2 1998 EN 61000 3 2 2004 EN 61000 3 3 2004 ...

Page 13: ... 9 1 1 2 1 5 2 0 KW With mechanic thermostat room temperature control No Auxiliary electricity consumption With electronic room temperature control No At nominal heat output elmax 0 4 0 5 0 75 0 9 1 1 2 1 5 2 0 KW Electronic room temperature control plus day timer No At minimum heat output elmin n d KW Electronic room temperature control plus week timer Yes In standby mode elSB 0 5 W Other control...

Page 14: ...rei Lager an den Händler geliefert werden Die Verpflichtung zur Garantieleistung unterliegt den nachfolgend aufgeführten Bedingungen und Bestimmungen Der Heizkörper wurde während des Transports den Versetzungen und der Installation nicht beschädigt und es wurden keine nicht ausdrücklich durch Dritte genehmigte Reparaturen und oder Manipulationen vorgenommen Das Material wurde vor der Installation ...

Page 15: ...der Widerstand ersetzt werden muss kann dieser Arbeitseingriff nur vom Hersteller seinem Beauftragten oder einer Person mit ähnlicher Qualifikation ausgeführt werden um jegliches Risiko zu vermeiden 10 Betriebsanleitung des Thermostats LCD Anzeige LCD Anzeige a Modus ON STANDBY Die Taste drücken um das Gerät einzuschalten oder den Modus Stand by zu aktivieren Im Modus ON zeigt das Display den Modu...

Page 16: ...dass der Raum zur gewünschten Zeit die gewünschte Temperatur erreicht hat Hinweis Die Funktion erfordert mindestens ein paar Tage derAktivierung um ihre maximale Effizienz zu erzielen Funktion Erfassung offenes Fenster Der Heizkörper kann erkennen ob ein Fenster geöffnet wurde da er eine schnelle Abnahme der Raumtemperatur feststellt In diesem Fall schaltet sich der Heizkörper für 30 Minuten aus d...

Page 17: ... EN 60335 2 43 2005 A1 2006 A2 2009 EN 55014 1 2008 EN 55014 2 1998 EN 61000 3 2 2004 EN 61000 3 3 2004 EN 61000 4 2 2009 EN 61000 4 4 2005 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 11 2004 EN 62233 2008 und die grundlegenden Anforderungen der folgenden europäischen Richtlinien erfüllen Richtlinie 2014 35 EU Richtlinie 2014 30 EU Richtlinie 2012 19 EU Richtlinie 2009 125 EG Richtlinie 2011 65...

Page 18: ... 5 0 75 0 9 1 1 2 1 5 2 0 KW Mit Kontrolle der Raumtemperatur über mechanischen Thermostat Nein Nebenverbrauch von Strom Mit elektronischer Kontrolle der Raumtemperatur Nein Bei Nennwärmeleistung elmax 0 4 0 5 0 75 0 9 1 1 2 1 5 2 0 KW Mit elektronischer Kontrolle der Raumtemperatur und Tageszeitschalter Nein Bei min Wärmeleistung elmin k A KW Mit elektronischer Kontrolle der Raumtemperatur und Wo...

Page 19: ...gado franco almacén del distribuidor El compromiso de otorgar la garantía está sujeto a las condiciones y disposiciones indicadas a continuación El radiador no debe haber sufrido daños durante el transporte el desplazamiento o la instalación y no se debe haber efectuado ninguna reparación o alteración sin la autorización expresa de parte de terceros El material debe haber sido almacenado en buenas...

Page 20: ...rio sustituir la resistencia la operación puede ser realizada únicamente por el fabricante por un delegado o por una persona con cualificación similar a fin de evitar cualquier riesgo 10 Instrucciones termostato Pantalla LCD Pantalla LCD a Modalidad ON STANDBY Presionar la tecla para encender el equipo o activara la modalidad Stand by En modalidad ON la pantalla muestra la Modalidad de la Temperat...

Page 21: ...ra configurada Notas la función requiere al menos un par de días de activación para lograr la máxima eficiencia Función Detección ventana abierta El radiador puede determinar si se ha abierto una ventana mediante la detección de un rápido descenso de la temperatura ambiente Si esto se produce el radiador se apaga por 30 minutos una vez transcurrido este tiempo el radiador restablecerá su funcionam...

Page 22: ...1000 3 3 2004 EN 61000 4 2 2009 EN 61000 4 4 2005 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 11 2004 EN 62233 2008 y por lo tanto cumplen con los requisitos esenciales de las Directivas Europeas Directivas 2014 35 UE Directivas 2014 30 UE Directivas 2012 19 UE Directivas 2009 125 EC Directivas 2011 65 UE Règlement EU 2015 1188 Morro D Oro el 03 12 2018 11 Eliminación Al finalizar su vida útil ...

Page 23: ... 5 2 0 KW Con control de la temperatura ambiente mediante termostato mecánico No Consumo auxiliar de energía eléctrica Con control electrónico de la temperatura ambiente No A la potencia térmica nominal elmáx 0 4 0 5 0 75 0 9 1 1 2 1 5 2 0 KW Con control electrónico de la temperatura ambiente y temporizador diario No A la potenza térmica mínima elmín n d KW Con control electrónico de la temperatur...

Page 24: ... D Oro TE ITALY C F Part IVA e Reg Impr TE n 00735570673 Cap Soc Euro 4 000 000 00 i v Tel 39 085 80 40 1 Fax 39 085 80 41 418 www cordivari com www cordivaridesign com UNI EN ISO 9001 14001 Q U A L I T Y ENVIRONME N T S Y S T E M Cod 1910000000078 nv00 ...

Reviews: