74
REPRODUCTION, EVEN IN PART, OF THE ILLUSTRATIONS AND/OR TEXT IS FORBIDDEN.
www.coral.eu
JETCLEAN DF
Series - edition 01/12
7.2.2. REPLACEMENT OF THE PNEUMATIC CLEANING COMPONENTS (TIMER)
The order of the removal of the components is shown in figure.
SCREW
CONNECTOR
GASKET
TIMER
GASKET
COIL
8. TROUBLESHOOTING
DEFECT
CAUSE
POSSIBLE SOLUTIONS
The air emitted is not
sufficiently purified
Inefficient action of the filters.
Check the state of cleanliness and replace
if necessary.
Decrease the intake air flow
Filters not cleaned.
• Check the operation of the timer,
electric and pneumatic systems.
• Intervene at the pause times of the
solenoid valves.
• Replace the filtering parts if necessary.
The fan vibrates
The rotor is not balanced.
Remove and clean the rotor.
The fan turns but suction is
insufficient
the rotation direction is
incorrect
Invert the two phases connected to the
engine.
Start failure
Incorrect connection.
Check the electrical connections.
9. SCRAPPING AND DECOMMISSIONING
The machine has no particular decommissioning problems. Appropriate precautions should be taken to prevent
it from being restarted by an unauthorized person.
For legal and tax issues (if any reports, complaints, etc ...), follow the current laws of the country where it is used.
WARNING!
Do not dump used filters, send them to specialist disposal companies in accordance with
local regulations.