7.1.1. ROUTINE MAINTENANCE OPERATION TABLES
A hour counter is connected to the electrical circuit to display the number of work hours of the equipment with
the need to provide the maintenance of the equipment.
OPERATION
24
hours
250
hours
500
hours
1000
hours
1500
hours
2000
hours
5000
hours
Check the state of the electrical and
pneumatic supply cables.
♦
♦
♦
Check the state of the cartridges through
the appropriate inspection door.
♦
♦
♦
Unload the contents of the wheeled
collection container.
♦
WARNING!
The operations listed above must be carried out by qualified personnel.
7.1.2. CLEANING
WARNING!
The incorrect cleaning or replacement of filtering media carries the risk of leakage to the
outside environment and of pollutant work.
7.2. EXTRAORDINARY MAINTENANCE
Operations not included among those listed as “routine maintenance” are considered extraordinary maintenance.
WARNING!
The extraordinary maintenance operations and repair of the machine are reserved for
qualified, trained and authorized personnel of the Manufacturer or Authorized Service
Centre.
7.2.1. CARTRIDGE REPLACEMENT
To
replace the cartridge
, follow this procedure:
STEP
ACTION
1
Undo the M8 fixing screws.
2
Remove the cartridge by turning it anticlockwise and proceed with the replacement.