5
Click on the
Learn
button
TAP
a magnet (i.e. from a Door/Window Sensor) to the vertical line mark on the side of the TX
−
E611 Sensor
A message will appear that a New Device Found
Enter a description under Sensor Name
Select the appropriate Sensor Type i.e. “2 24 Hour Audible”
Select “12 Water Leakage” for Sensor Option
“Tamper” should be defaulted as checked and do not check “Disable Internal Reed”
Select Voice Name(s) at the bottom
Click
Save
at the top when finished
Click
OK
if a popup message appears to confirm your changes
Learn the TX
−
E611 Water/Freeze Sensor to the Côr Panel as a Freeze Sensor
Select
Sensor to Configure
for the next available slot i.e. “6 Sensor”
Click on the
Learn
button
HOLD
a magnet (i.e. from a Door/Window Sensor) for at least
2 Seconds
to the vertical line mark on the side of the TX
−
E611 Sensor
A message will appear that a New Device Found
Enter a description under Sensor Name
Select the appropriate Sensor Type i.e. “2 24 Hour Audible”
Select “13 Low Temp” for Sensor Option
“Tamper” should be defaulted as checked and do not check “Disable Internal Reed”
Select Voice Name(s) at the bottom
Click
Save
at the top when finished
Click
OK
if a popup message appears to confirm your changes
Step 10 — Learn the IS
−
ZW
−
LM
−
1 Z
−
Wave Light Dimmer to the Côr Panel
Go to
Settings
and select
Zwave Add/Remove
from the dropdown menu under Settings Selector
Click
Add
button
Press the center button repeatedly on the Z
−
Wave device
The device will display under the Zwave Device Selector field when the panel learns the device
(Optional) Select the Device Room Location created earlier
Enter a description under Device Name
Click
Save
at the top when finished
Click
OK
if a popup message appears to confirm your changes
Step 11 — Add Wi
−
Fi Credentials; Create Web Access Passcode and Download Access Code
Go to
Settings
and select
Network
from the dropdown menu under Settings Selector
Under Wi
−
Fi Configuration, enter the login credentials found on the sticker underneath the TP Link Router
Wi
−
Fi SSID = myHVACxxxxxx (case sensitive)
Wi
−
Fi Security Type = WPA2 Passphrase
Wi
−
Fi Password = Security Key (8 digit number)
Change the Web Access Passcode to an eight (8) digit number that you and homeowner agree to use e.g. 4 digits of a number repeated
twice ’12341234’
TIP: Write down this Web Access Passcode and panel serial number in the Homeowners Quick Start Guide (01
−
811
−
20439
−
01) brochure in
the Starter Kit.