Page 1: ...1 Operation Manual of Outdoor High Speed Pan Tilt with Infrared Lighting VER 2 0 Pleasereadthemanualcarefullybeforeusingtheproduct SafeNote ...

Page 2: ...ntainedbyqualified Thearrowheadsighshinedintriangletoreminduserthenon insulated dangerousvoltageappearingneartheproductisdangeroustohuman beings The note sign in triangle is to remind user refer to the spec on important operationandmaintenance TheserialNO issignedatthebottomorside PleasefilltheserialNO intheblank below andkeepthespecwelltocheckwhenneeded Content ...

Page 3: ...ENU 13 2 2 2DISPLAYSETUP 13 2 2 3CAMERASETUP 14 2 2 4CONTROLSETUP 14 2 2 5HOMEOPTION 15 2 2 6CAMERAMASKSET 15 2 2 7PROGRAM 15 2 3 Menuappendix 16 2 3 1Patrolprogramoperation 16 2 3 2Presettitleprogramoperation 17 ThethirdchapterP T Zparametersetup 18 3 1End meetresistancesetup 18 3 2Addressdialsetup 18 3 3Protocolandacquiescentbaudratesetup 20 3 4P T Zcommunicatebaudratesetup two bitsafterSW2 20 T...

Page 4: ...n 24 4 7Installationspec 25 4 7 1SunShield installation 25 4 7 2OnVehicleinstallation 25 4 7 3Wallinstallation 26 4 8P T Zlineoutway 27 Appendix Usualtroubleanalysis 29 Appendix 24VACdistancerelationbetweenrouteandtransmissiondistance 30 Appendix lightningstrikeproof surge 31 Appendix Maintenanceserviceterms 32 ...

Page 5: ...deliveryorreturnforrepair ifthereisnopartinsidethe product thenneedsrepairbycustomerhimself Installcarefully Read the manual carefully before installing the product Take the module gently do not press structure parts otherwise the machinery trouble will be caused Transparent cover is advanced optic products avoiddirectlytouchresultinscratchesonthecover effectimagequality Thecompetencyrequirementon...

Page 6: ...rspecificationsof powersupply z Pleasedon tdismantlepartsinsidedevicetoeffectusing thereisnopartsinsidecanbemaintainedby userhimself z Donotaimthecameraatthesunorverybrightobject aimormonitorbrightandstillobjectforalong timewhetherthepowersupplyofthecameraisswitchedonoroff Thewholemachinecanbekeptrepairfor3years Remark thecameraiskeptrepairfor1year ...

Page 7: ...pleoperationetc 1 1Pan TiltSpecification Power Supply AC24V 10 2 5A PowerConsumption 50VA Weight 7 5Kg InstallationStyle PlainBaseInstallation RelativeHumidity 10 90 OperationTemperature 35 55Ԩ WaterproofClass IP66 1 2BasicFunctionsofPam Tilt Panpresetspeed 80 s Tiltpresetspeed 60 s Pan speed 0º 60 s Tilt speed 0º 40 s PresetPosition 128positionsinmaximum PatrolFunction 6patrolpatternsarestoredinm...

Page 8: ...Horizontal Resolution 480TVL Effective Pixels PAL 752 582 440K 758 592 450K 795 596 470K NTSC 768 494 380K 758 504 380K 811 508 410K LowestLUX 1Lux 0 01Lux 0 2LuxF1 6 1Lux 0 01Lux 1Lux 0 01Lux Iris Automatic Manual Focus Automatic Manual Zoom Optic18 Optic22 Optic23 Optic27 f 4 1to73 8mm f 4to88mm f 3 6to82 8mm f 3 6to98mm Angleofview Wide 48 Wide 47 Wide 54 TELE 2 7 TELE 2 2 TELE 2 5 Backlight Co...

Page 9: ...s Smoothrunningatlowspeedwithsuperlowernoise Imageshavenofluttering Panoramicmonitorwithoutblackspotandthepositioningaccuracycanreach 0 1 1 6 3HighDegreeofIntelligence Presetmemoryhasasmuchas128positions Dataarekeptinmemoryevenpowerisfailure Horizontal scan between two positions are supported Scan speed can be altered and direction of pancanbeselectedfreely Thepan tiltcanmakescanlargerorsmallertha...

Page 10: ...ionstatemanually Otherfunction refertodifferentcamerabyusingsystemmenutocontrol 1 6 5InfraredSystem Theinfraredsystemisnormallyunderautomaticcontrolstate Theinfraredlampshallactfollowed byopen closeofthelowilluminationofthecamera Theopen closestateoftheinfraredlampcanbechangedbythemenumanually The default option on the menu of the infrared lamp is OFF Normally the system detects external illuminat...

Page 11: ...nputsignal suchasvoltagesignal coulddamagethedomecamera Incasemultiplechannels have alarm signals the pan tilt shall response upon them on by one with the interval of 2 seconds The pan tilt shall do not response upon functions such as pan patrol and self study whenthealarmsignalininputted ...

Page 12: ...kabsorberisadded seepicture2 A B C D E F G H SELECTED ON LINE R S485 BU S Al ar m Picture2 2 SchematicDrawingofCommonPan tilt seepicture3 Modem Bank Vi deo D C 12V AC 220V R S485 D C 12V DC AC I nver t er St or age bat t er y M oni t or PTZ C ont r ol l er Tel ecom m uni cat i on Picture3 AlarmBox Keyboard DVR Monitor Videoinput ...

Page 13: ...y title isplayofthepresserpositionandthedisplayofthecameraitself CAMERASETUP Toenterintothesub menuofthecommondataof thecamera CONTROLSETUP Toenterintothesub menuofthecontroldataof thepan tilt CAMERAMASKSET Toenterintothesub menuofthecontroldata ofthecameramask PROGRAM Toenterintothesub menuoftheenhancefunctionofthemenu PAL CAMERA PAL NTSC To switch modes of PAL NTSC being identical with that of t...

Page 14: ...efunction ON Open OFF Close ALAWYS Openalways RETURN Toreturntothemainmenu 2 2 3CAMERASETUP SLOW SHUTTER frame accumulation function with options of manual automatic Under automatic state when the display of the camera is opened ASS shall be displayedonthescreen OnlySonycameracandisplayASS BACKLIGHT backlightcompensationopen close ICRSHOT lowillumination ON manual AUTO automatic D ZOOM Tosetupdigi...

Page 15: ...y isclosedafter3minutes RETURN Toreturntothemainmenu 2 2 5HOMEOPTION AUTOHOME WhenitissetatON theautomatichomeisopened It means if theuserhasno anyfunctionin aperiodof time thepan tilt shall return home HOME The pan tilt couldn t return home automatically if the pan tilt is at patrol state If no home returning is neededwhenthepan tiltisunderstopstate setthisoptionatOFF HOME POS HOME is the returni...

Page 16: ...onisjusttheendposition thedomecamerashallmake360 pans The speed of the pan is divided into six grades FAST NORMAL SLOW FAST NORMAL SLOW Thefirstthreegradesarethepanlessthan180 whiletherearthreegradesarethepanlarger than180 AdjustspeedbyPANLEFT PANRIGHTandpressOPENbuttontoexitthemenu The startpositionandtheendpositionofthepancanbesetupbyoptions1and2ofthemenu SETTITLE topanbetweentwopositions Please...

Page 17: ...nderEditState AfterenteringintoEditstate operations onthescreenareasfollows The prompt messages are displayed on both op and bottom lines and information of every pattern is displayed in the middle of the screen One line includes data of two patrol positions Move the cursor by PAN LEFT RIGHT and change values by TILT UP DOWN Press down buttons for more than one secondtospeedupoperation PressCLOSEb...

Page 18: ...displayonthescreenisshownasfollows fromthedrawingwecanfindthecurrentsetupisthefirstpresetpositionwiththe titleof NOTITLE MovethecursorbyPANLEFT RIGHTandchangevalues byTILTUP DOWN Pressdownbuttonsformorethanonesecondtospeedup operation PressCLOSEbuttontoexittheEditstateandstoretherevisions Thetitleofthepresetposition caninclude8charactersinmaximumsuchas0 9 A Z andblank Note thefirstlettershouldbe0 ...

Page 19: ...is at 1 2 state 120 Ω terminal resistorisconnectedinparallelwiththebus485 InthebusRS485system thereisonlyonepan tilt which hastheterminalresistortobeconnectedinthecircuitandotherpan tiltswhoseterminalresistorsareopened soastoincreasethereliabilityofthesystem Generally theterminalresistorofthepan tiltatthefarthestend fromthecontrolcircuitisconnectedandallterminalresistorsofotherdevicesareopened 图1 ...

Page 20: ... OFF 7 ON ON ON OFF OFF OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF ...

Page 21: ... ON B01 ON OFF OFF OFF OFF ON NEON ON OFF OFF OFF OFF ON SANTACHI OFF ON OFF OFF OFF ON PELCO P D ON ON OFF OFF OFF OFF PELCO MK OFF OFF ON OFF OFF OFF PANASONIC ON OFF ON OFF OFF ON LONGCOMITY OFF ON ON OFF OFF ON HUNDA600 ON ON ON OFF OFF ON LILIN OFF OFF OFF ON OFF ON VICON ON OFF OFF ON ON OFF MOLYNX OFF ON OFF ON OFF ON KALATEL ON ON OFF ON ON OFF VCL OFF OFF ON ON OFF ON RESERVED ON OFF ON O...

Page 22: ...ence B01 9600Bps O N 1 2 3 4 5 6 PELC O P D 2400Bps O N 1 2 3 4 5 6 O N 1 2 3 4 5 6 PAN ASO N I C 9600Bps O N 1 2 3 4 5 6 KALATEL 4800Bps O N 1 2 3 4 5 6 U l t r ak 9600Bps O N 1 2 3 4 5 6 ALEC 9600Bps O N 1 2 3 4 5 6 O N 1 2 3 4 5 6 PELC O P D 4800Bps PELC O M K 4800Bps ...

Page 23: ...nnectionsrefertothedescriptionfiles 3 There are sophisticated optical and electronic components inside the product Avoid incorrect operationmethodssuchasheavypressingorstrongvibrationduringthecourseoftransportation store andinstallationotherwisetheproductcouldbedamaged 4 Pleasedonotdismountcomponentsinsidetheproducttoavoidoccurrenceoftrouble Thereisnopart insidetheproduct whichneedsrepairbycustome...

Page 24: ...ntsof systemanti jammingandelectricsafe anddon tshortconnectormixconnectwithstrongelectricnet zeroline Whensystemearthseparately earthresistanceisnomorethan4Ω sectionsquaresofearth linesmustnomorethan25mm2 lineshortconnect Theproduct adoptTVSplatelightningstriketechnology canpreventdamagetoinstantaneouslightning strike surgeandsoonkindsofpulsesignaloflowerthan1 5KWpowerefficiently But aboutinstall...

Page 25: ...rolline videoline powerlineintorelativesockets linewayaccordingtospecificationonsystemcontrol line video line power line remarks strictly to do self inspection after electric P T Z will carry out default setup donormalinstallationafterself inspectionisok 4 5 6PleasekeepallpackingdocumentsinP T Z After open P T Z packing please keep original packing documents in P T Z well in order to packing P T Z...

Page 26: ...ubsequentpartinthemanual operation 4 7Installationspec Prepare 1 Removethebottomplateofthepan tilt 2 Set the corresponding information in accordance with the schematic drawing of the dip switch of addresses protocolsandbaudrates 3 Installthebottomplateofthepan tiltandtakecareofthetightnessofwaterproofsealring seepicture2 ...

Page 27: ...steelscrews and43 2 8 0 7fourfluorinewashers onescrewcorrespondsonewasher seepicture3 M3x5crossedstainlesssteelscrew fourfluorinewasher Picture3 4 7 2Vehicle carriedinstallation 1 Take out the Vehicle absorber take the underpan as templet drill four installation holes on the bracketwhichneedsbeinstalled seepicture4 2 Prepare4therightlengthboltsaccordingtoyourrequest fixtheabsorberwithflatpillowand...

Page 28: ...latpillow nut Picture6 4 7 3Wallinstallation51 Takethewallbracketoutofpacking usetheunderpanastemplet drill4M8 metalbulgyboltholesonthesurfacewithstrikeelectricdrill fitonbulgytubeseparately seepicture7 1 Takethewallbracketoutofpacking usetheunderpanastemplet drill4M8metalbulgyboltholeson thesurfacewithstrikeelectricdrill fitonbulgytubeseparately seepicture7 Installation ...

Page 29: ...e bracketonthewallwith4M8boltsandoneφ8flippillow 2φ8 φ18stainlesssteelflatpillows seepicture 8 3 ThenfixP T Zonthewallbracketwith4M8x30stainlesssteelboltsandflatpillow flippillow nuts seepicture9 Picture8 M8bolts picture9 M8bolts 1flippillow 2flatpillow 1flippillow 2flatpillow nuts 4 8 p t zlineoutway 4 8 1Descriptionof7 CoreTerminalseepicture10 ...

Page 30: ...rminal picture10 Description S N MEAN 1 DC12V AC24V RED 2 GND AC24V BLACK 3 R communication YELLOW 4 Null 5 R communication ORANGE 6 V VF 7 V VF Descriptionof7 CoreTerminallineout 4 8 2Descriptionof10 CoreTerminalseepicture11 ...

Page 31: ...on S N MEAN 1 Alarm 1in RED 2 Alarm 2in ORANGE 3 Alarm 3In YELLOW 4 Alarm 4In GREEN 5 NC 6 AlarmInCOM BLACK 7 AlarmOutCOM WHITE 8 NC 9 AlarmNOout BLUE 10 AlarmNCCOM GREY Remark 10 CoreTerminalisusedforalarmsystem detailedlinerefertoconnectpolecolorspec ...

Page 32: ...Successfulself inspection withoutcontrol Wrong connection of control signal wires Makecorrection Mismatchedaddress Re select Mismatchedprotocol Make mismatch of protocol and controller andrestart Unstableimages BadcontactofVFcircuit Remove Insufficientelectricpower Replace Domepan tiltoutofcontrol Abnormalself inspection Restart Badcontactofcontrolcircuit Remove Operation of main machine has probl...

Page 33: ...nchformtransformer Routing mm Trans dis feet m 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 61 100 28 8 45 13 71 21 181 55 110 25 7 41 12 65 19 164 49...

Page 34: ...ies mustadopthermetictubecoverupinearthwaytorouting andadoptonepoint forbid routinginairabsolutely z Instrongthunderstormorhighinductivepressurearea suchashighpressuretransformersubstation mustadoptextrapowerequipmentandinstalllightningrodandsoonmeasures z outdoorequipmentanddesignonroutingofdefendthunderandearthshouldbeconsidereduniformly connectingrequirementonbuildingdefendthunder z systemshoul...

Page 35: ...orfree Warrantyperiodofallpartswhichhaverepairedorreplacedis90daysaftersendingoutcargoes Products can t be repaired for free for manpower cannot dispute reason such as war earthquake lightningstrike improperuse deviantoperation revise normalfrayorproblemcausedbyaccident Manufacturer take on no responsibility on p damage and loss caused by product special use or application The compensation on fell...

Page 36: ...rydate orderNO saleorderNO ormanufacturerinvoice Detailedproblemphenomenon If having disputes on repair for free terms hereinbefore please attach written explanations when returning products 3 Return Forreturningcargoesquickly pleasecontactmanufacturertoget repairNO thenarrangesendingcargoes to manufacturer Allreturned cargoesshould mark RAN clearly Delivery way ofreturningcargoes is the same as w...