Cool Energy EcoStore Heat Pump Water Heater
30 |
P a g e
For a correct and competent maintenance, it is necessary to evacuate/ leak the refrigerator circuit (
draining and filling)!
5.9 Anode verification
(periodic)
The device is protected against corrosion by an electronic anticorrosion anode for protection against
the effects of spurious currents that could damage it.
The control is performed
without
clearing out the tank.
You must replace the anode in case of wrong working.
CAUTION:
U
a wrong functionality of the anode reduces the last of the device.
In case of necessary substitution of the anode please do the following operations:
L1 Blue
L2 Green
Signaling
OFF
OFF
Not powered device
ON/lightening
ON/lightening
Working device / right protection
lightening
lightening
Short circuit electrode ( simultaneous lightening )
lightening
lightening
Disconnected electrode / no water ( alternate lightening