Electrical connection
All installation work must be carried out by a competent
person or qualified electrician.
Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate
inside the cooker hood.
Warning: THIS APPLIANCE MUST BE EARTHED.
Mains Supply could be connected to the Mains Voltage by Direct Connection
USE A 16 AMP FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE ON
EUR
UK
Warning
Make sure the fused spur outlet is located in an accessable position.
Direct Connection
If the appliance is being connected directly to the mains an omnipolar circuit-
breaker must be installed with a minimum opening of 3mm between contacts.
If the cable is damaged or to be replaced, the operation must be carried out the by
a qualified electrician with dedicated tools to avoid any accidents.
The installer must ensure that the correct electrical connection has been made
and that it complies with wiring diagram.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorized technicians only.