
Product information
- 12 -
EN
1. Setting up the appliance
Appliance dimensions:
Without
packaging
With
packaging
Width
515 mm
580 mm
Depth
599 mm
730 mm
Height
627 mm
800 mm
Weight
45 kg
60 kg
•
Appliance must be installed level
Safety distances:
•
Left-right
: 50 mm
•
Back
: 50 mm
•
Above
: 500 mm (ventilation)
2. Connecting to the electrical supply
Either alternating current 1/N/PE 230V 50/60Hz
or three-phase current 3/N/PE 400V 50/60Hz
(can be converted on site by CONVOTHERM
authorised service partner)
1/N/PE
230V
3/N/PE
400V
Connected wattage [ kW]
3,0
5,7
Rated current [A]
13,1
11,8
Cable cross section* [mm²]
3 x 2.5 5 x 2.5
* recommended cable cross section open-air laid
at max. 5 m in length.
•
Main switch (all-pole separator) is to be
installed by the customer in the vicinity of the
appliance.
•
Connection for potential compensation.
•
WARNING 1/N/PE connection causes
considerable power reduction and therefore
extension of the cooking time.
3. Connecting to the water supply:
•
Cold water ¾” 2 to 6 bar flow pressure
•
Water tap and filter are to be installed by
the customer in the vicinity of the
appliance
•
Water: Drinking water quality with
Total hardness:
5-7°dH
(soft water)
pH:
6.5 to 8.5
Conductivity: 10-200µS/cm
Cl
-
: max
100mg/l
SO
4
-
: max
400mg/l
Fe: max
0.1mg/l
Mn: max
0.05mg/l
Cu:
max 0.05mg/l
Cl
2
: max
0.1mg/l
if necessary, install water treatment
4. Water
drainage
DN 40, recommended tundish funnel or
fixed connection
5. Ventilation
Sensible heat output 1100 kJ/h
Latent heat output 1000 kJ/h
6. Other
data:
Splash protection
IPX4
Conformity marking
CE
Noise emission:
< 70 dBA
Inserts 2/3 GN (325x354mm)
6
Shelf spacing
50 mm