background image

Manual CC 5201 

14

 

Control via the RS-485 Interface  

 

The camera can be controlled by using an external controller equipped with RS-485 communications.  
 

 

To control using a DVR or keyboard controller Connect the RS-485 cable (TRX+, TRX-) to the 

connection port of the 485 control board in the DVR or controller. 

 

485 Control Board Connection Port 

RS-485 Control Port 

(+) CONNECTION TERMINAL (TRX+) 

485+ 

(- ) CONNECTION TERMINAL (TRX -) 

485- 

 

* RS-485 communication default initial values 

 

Item 

Camera ID 

Baud Rate 

Uart Mode 

Pet Pkt 

Initial Value 

9600 

8-NONE-1 

ENABLE 

 

 

Note 

To control the camera use Pelco-D protocol. 
(Go Preset 95: Enters into OSD menu or Set key function) 
 
 

 

 

Camera Operation 

 

Menu 

 

Main Menu 

Exposure 

Lens, Brightness, Backlight, Shutter, AGC, Sense up, Eclipse, DNR 

White Bal 

WB Mode, Red Cont, Blue Cont, Push Auto 

Day / Night 

D/N Mode, Filter Dly 

Motion 

Detect Mode, Detect Area, Sensitivity, Alarm Time 

Privacy 

Area, Mask, Level, Top, Down, Left, Right 

Option 

Title, Nega/Posi, Sharpness, Mirror, Zoom, Pan/Tilt, Phase 

Display 

Title, Motion Det, Camera ID, Baud Rate 

Sync Int, 

Auto 

Initial  
Exit  
 

Switch 

 

Set:

 On or Off of OSD Menu 

-

 

It becomes a decision at the title screen 

 

Up / Down:

 Up or Down of Cursor 

Summary of Contents for CC-5201

Page 1: ...Manual CC 5201 1 Manual CC 5201 Date January 2011 Convision Systems GmbH...

Page 2: ...de reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not install...

Page 3: ...t for a long period a fire may be caused Do not install the camera on a surface that can not support it If the camera is installed on an inappropriate surface it may fall and cause injury Do not hold...

Page 4: ...iew 9 Installation Procedure 10 Lens 10 Using an Auto Iris Lens 10 Using a C CS mount Lens 11 Connecting to a Monitor 12 Connecting to Power 13 Control via the RS 485 Interface 14 Camera Operation 14...

Page 5: ...nded by manufacturer 6 Power source This product should be operated only from the type of power source indicated on the marking label Precautions Operating Before using make sure power supply and othe...

Page 6: ...httime conditions to enhance the definition of the image Electronic IRIS The electronic Iris function enables continuous automatic control of the shutter between 1 60 1 50 1 120 000 sec Privacy Functi...

Page 7: ...C Mount Adapter 4 Instruction Manual Overview Front View 1 Tripod Mounting Bracket Screw Hole Used to fix Tripod Mounting Bracket to the top of the camera 2 C Mount Lens Adapter Install this adapter t...

Page 8: ...camera onto a bracket or tripod The screw sizes for this hole are as follows The Tripod Mounting Bracket can be unscrewed and installed on the top or bottom of the camera Make sure to use the Tripod M...

Page 9: ...y or Night Mode by connecting an external signal to this port 8 MD Output Port Motion detection signal is output through this port 9 RS 485 Control Port The SETUP MENU can be controlled via this port...

Page 10: ...lens surface clean as the picture quality suffers if there is dirt or fingerprints on the Lens Using an Auto Iris Lens 1 Strip 8mm of insulation from the end of the Auto Iris Lens cable 2 Strip 2mm of...

Page 11: ...a simple modification is required When Using a CS Mount Lens Remove the protective cover from the front of this product and turn the CS Mount Lens clockwise to install it Focus the camera using the CS...

Page 12: ...2 Turn the C Mount lens clockwise to install it 3 Focus the camera using the C Mount Lens and Back Focus controls 4 Set the lens selection switch located on the rear of the camera to either DC or VIDE...

Page 13: ...ower as shown in the following figure For AC DC Power Check the standard power requirement before connecting to power Dual Power Type AC90 230V 50Hz 60Hz 4 5W AC 24V DC 12V AC 24V Class2 DC Power Type...

Page 14: ...Rate Uart Mode Pet Pkt Initial Value 1 9600 8 NONE 1 ENABLE Note To control the camera use Pelco D protocol Go Preset 95 Enters into OSD menu or Set key function Camera Operation Menu Main Menu Expos...

Page 15: ...t OFF or ON can be selected Shutter 1 60 NT FLC 1 250 500 1000 2000 4000 10000 can be selected When LENS is DC it is possible to select it Another becomes NOT USE It becomes 1 60 at NTSC It becomes 1...

Page 16: ...AWC OFF to PUSH can be selected Another becomes NOT USE Return It returns to the Main Menu Day Night D N Mode AUTO DAY NIGHT EXT can be selected Filter DLY When it is AUTO 4 to 10 can be selected When...

Page 17: ...N BLC automatically becomes effective on this screen Privacy Area 1 to 4 can be selected Mask OFF or ON can be selected Level When Mask is ON 0 to 15 can be selected It set the same value regardless o...

Page 18: ...DOWN LEFT RIGHT Phase You can select a desired phase between 0 and 524 when the Sync menu is fixed to the AUTO mode Return It returns to the Main Menu o Title It moves by UP DOWN LEFT and RIGHT Chara...

Page 19: ...9600 pbs Return It returns to the Main Menu Sync Two synchronisation modes are available INTERNAL and AUTO In AUTO mode it synchronises the video signal between cameras without a synchronous generato...