Manual CC 5201
14
Control via the RS-485 Interface
The camera can be controlled by using an external controller equipped with RS-485 communications.
To control using a DVR or keyboard controller Connect the RS-485 cable (TRX+, TRX-) to the
connection port of the 485 control board in the DVR or controller.
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL (TRX+)
485+
(- ) CONNECTION TERMINAL (TRX -)
485-
* RS-485 communication default initial values
Item
Camera ID
Baud Rate
Uart Mode
Pet Pkt
Initial Value
1
9600
8-NONE-1
ENABLE
Note
To control the camera use Pelco-D protocol.
(Go Preset 95: Enters into OSD menu or Set key function)
Camera Operation
Menu
Main Menu
Exposure
Lens, Brightness, Backlight, Shutter, AGC, Sense up, Eclipse, DNR
White Bal
WB Mode, Red Cont, Blue Cont, Push Auto
Day / Night
D/N Mode, Filter Dly
Motion
Detect Mode, Detect Area, Sensitivity, Alarm Time
Privacy
Area, Mask, Level, Top, Down, Left, Right
Option
Title, Nega/Posi, Sharpness, Mirror, Zoom, Pan/Tilt, Phase
Display
Title, Motion Det, Camera ID, Baud Rate
Sync Int,
Auto
Initial
Exit
Switch
Set:
On or Off of OSD Menu
-
It becomes a decision at the title screen
Up / Down:
Up or Down of Cursor