Manual CC 5201
13
Since the connection procedure may differ depending on the type of monitor or peripheral
device to be connected, refer to the User Manual for the device to be connected.
Make sure to turn off the device to be connected before making any connections.
Turn the 75
Ώ
/Hi-Z switches of interim display devices to the Hi-Z position, and the switches of
any final device to the 75
Ώ
position.
Connecting to Power
Since power specifications differ depending on the model, make sure to check your model name and
specifications before connecting power. You can connect power as shown in the following figure.
For AC / DC Power
Check the standard power requirement before connecting to power.
Dual Power Type
AC90~230V-50Hz/60Hz 4.5W
(AC 24V/DC 12V, AC 24V Class2)
DC Power Type (DC 12V, 500mA)
When the resistance value of cooper wire is at [20°C(68°F)]
Copper wire size
(AWG)
#24(0.22mm²)
#22(0.33mm²)
#20(0.52mm²)
#18(0.83mm²)
Resistantce value (
/m)
0.078 0.050 0.030 0.018
Voltage drop (V/m)
0.028
0.018
0.011
0.006
As shown in the table above, voltage decreases as the wire gets longer. Therefore use of an
excessively long adaptor output line for connection to the camera may affect the performance of the
camera.
Standard voltage for camera operation: DC 12V ± 10%, AC 24V ± 10%
There may be some deviation in voltage drop depending on the type of wire and the
manufacturer.