System Requirements
•
HDMI equipped source devices, connect with HDMI cables or DVI
equipped source, connect with DVI to HDMI cables
•
HDMI equipped displays (TVs or monitors) or HDMI equipped AV
receivers, connect with HDMI cables
•
Industry standard CAT5e/6/7 cables
•
HDBaseT™ Receivers (i.e. CH-506RX, CH-507RX or CH-1109RX)
•
Network Router with internet connection for LAN serving
Operation Controls
and Functions
The following sections describe the hardware components of the unit.
Front Panel
1
LCM :
Displays the setting information of each input and output setting.
2
POWER:
Press this button to power the device on/off. The LED will illuminate green when
the power is on, red when it is in 'Standby' mode.
3
LOCK:
Press this button to lock all the buttons on the panel; press again to unlock. The
LED will illuminate green when locked.
4
IR Window:
IR Receiver window (accepts the remote control signal of this device only).
5
MENU:
Press this button to access the LCM menu system, from here EDID settings can
be managed and IP system settings are displayed.
6
IN/OUT and 1~8/A~H:
Press the OUT button and then the number buttons to select the required output
ports, and press IN button and then a single number button to select the required
input source, finally press the MENU button to confirm the selection. For example,
if outputs A~D need to be set to input 1 and outputs E~H need to be set to input
2, then the following sequence of button presses need to be performed:
Press: OUT
→
A
→
B
→
C
→
D
→
IN
→
1
→
MENU,
and then press: OUT
→
E
→
F
→
G
→
H
→
IN
→
2
→
MENU.
Note: