Note: The IP address of the Matrix can be displayed on the device's LCM
monitor   by   pressing   the   Menu   button   twice.   Type   'HELP'   to   list   the
available commands (see below for reference).

Type   'IPCONFIG'   To   show   all   IP   configurations.   To   reset   the   IP,   type
'RSTIP' and to use a set static IP, type 'SETIP'.

Note:
1.All commands will not be executed unless followed by a carriage return. 
Commands are case-insensitive.
2.If the IP is changed then the IP Address required for Telnet/WebGUI 
access will also needs to be changed accordingly

Summary of Contents for 15204

Page 1: ...HDMI 8x8 HDBaseT Matrix over CAT5e 6 7 with LAN Serving 15204 Operation Manual ...

Page 2: ...Supports distances up to 100 meters through CAT6 7 cables Supports 3D signal display dependent upon the output display EDID settings Supports PoE Power over Ethernet on compatible receivers only Supports HDMI input up to 15 meters at 8 bit resolution or 10 meters at 12 bit resolution Supports bi directional IR from input and output locations Supports RS 232 remote control on panel control and IP C...

Page 3: ... LOCK Press this button to lock all the buttons on the panel press again to unlock The LED will illuminate green when locked 4 IR Window IR Receiver window accepts the remote control signal of this device only 5 MENU Press this button to access the LCM menu system from here EDID settings can be managed and IP system settings are displayed 6 IN OUT and 1 8 A H Press the OUT button and then the numb...

Page 4: ...eived from IR IN 1 8 4 ALL IR IN Connect an IR Receiver to this IR input Ensure that remote being used is within the direct line of sight of the IR receiver It will transmit all IR signals received from IR IN 1 8 and IR IN ALL to IR OUT 1 8 and IR ALL OUT 5 SERVICE Manufacturer use only 6 IR OUT 1 8 Connect the IR blasters to the IR outputs Place the IR blaster in direct line of sight of the equip...

Page 5: ...l power PoE Power over Ethernet capable receiver units Side Panel 1 Fan Ventilator These are air ventilation areas DO NOT block these areas or cover it with any object Please allow adequate space around the unit for air circulation Remote Control 1 Power Press this button to switch on the device or set it to standby mode 2 1 8 IN Input ports selection 1 8 3 A H OUT Output ports selection A H IR Pi...

Page 6: ...8 B1 B8 Switch Output B to 1 8 C1 C8 Switch Output C to 1 8 D1 D8 Switch Output D to 1 8 E1 E8 Switch Output E to 1 8 F1 F8 Switch Output F to 1 8 G1 G8 Switch Output G to 1 8 H1 H8 Switch Output H to 1 8 ABCE 1 ABCD 8 Switch Output ABCD to 1 8 at the same time SETIP IP SubNet GW Setting IP SubNet GateWay Static IP RSTIP IP configuration was reset to factory defaults DHCP IPCONFIG Display the curr...

Page 7: ...m being used are connected to the same active network To access the Telnet control in Windows 7 click on the Start menu and type cmd in the Search Field then press Enter see below forreference Under Windows XP go to the Start menu and click on Run type cmd then press Enter Under Mac OS X go to the file menu then navigate to Go Applications Utilities Terminal see below for reference Once in the Com...

Page 8: ...e below for reference Type IPCONFIG To show all IP configurations To reset the IP type RSTIP and to use a set static IP type SETIP Note 1 All commands will not be executed unless followed by a carriage return Commands are case insensitive 2 If the IP is changed then the IP Address required for Telnet WebGUI access will also needs to be changed accordingly ...

Page 9: ... status control and User setting pages Click on the Control tab to control power input output ports EDID and reset mode Clicking on the User Setting tab allows you to reset the IP configuration The system will ask for a reboot of the device every time any of the settings are changed The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entr...

Page 10: ...24V 6 25A DC US EU standards CE FCC UL certified ESD Protection Human body model 8kV air gap discharge 4kV contact discharge Dimensions 438mm W x 255mm D x 92mm H Weight 4268 g Chassis Material Metal Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Power Consumption 20 90 RH non condensing Relative Humidity 84W TX Main 52W RX PoE ...

Page 11: ...Connection Diagram ...

Reviews: