background image

PRODUCT FEATURES

Designed to provide the perfect combination of patient safety, weight 
capacity and maneuverability. This lift is manufactured to meet the needs of 
the general patient population in hospitals and nursing homes. Caregivers 
appreciate the ease of operation and patients are reassured by the stability 
and overall comfort provided.

•  600 Lb. safe working loads
•  Heavy duty multi tilt spreader bar
•  Low base
•  Digital scale accessory 
•  Emergency lowering device

DESCRIPTION

& APPLICATIONS

5

PR
ODUCT

FEA

TURES

Summary of Contents for ConvaLift CL600E

Page 1: ...according to the instructions in this manual All operators should have received or read and understood the instructions for safe and proper operation of the patient lift ConvaQuip CL600E shown ConvaL...

Page 2: ...omplete and free from any shipping damage Refuse delivery if the packaging appears to be badly damaged If the merchandise is received damaged or is missing components contact the shipping company imme...

Page 3: ...uld be used solely for transferring a user patient from one utility beds chairs toilets etc to another The patient lift should not be used for transporting or moving any patient from one location to a...

Page 4: ...d the instructions in the manual before using the product Note Important information concerning the product and or its correct and proper usage follows Symbols used in this manual and their meanings I...

Page 5: ...needs of the general patient population in hospitals and nursing homes Caregivers appreciate the ease of operation and patients are reassured by the stability and overall comfort provided 600 Lb safe...

Page 6: ...r Yes Emergency Release Yes Weigh Scale Optional SPECIFICATIONS OPTIONS 6 ConvaQuip is committed to continuous improvements of our products therefore the specs dimensions and features listed above are...

Page 7: ...any missing parts Contact you dealer immediately if a part is missing ASSEMBLY Parts List for CL600E CL600E D 1 Boom 2 Mast 3 Base 4 Spreader bar w Sling hooks 5 Pendant Hand Control 6 Actuator 7 Cont...

Page 8: ...m the bottom of the mast and base Pull the Mast to an upright position Re insert the bolts into the holes at bottom of the mast and tighten the nuts 1 Attach boom to top of mast Re insert the bolts in...

Page 9: ...nted at the bottom of the Mast Line up the control box with the hole at the top of the mast and insert the screw to hold the control box in place Secure the control box by turning the lock mechanism i...

Page 10: ...Attach the top of the Actuator to the bracket on the Boom and insert pin Insert keeper ring through hole in pin to secure actuator to upper bracket 4 A B ACTUATOR ASSEMBLY FOR CL600E CL600E D 10 ASSE...

Page 11: ...INS FOR E series 6 Attach actuator and pendant to the control box Pendant Plug Actuator Plug AC Power Plug refer to page 14 for charging instructions 7 Tighten all nuts and make sure lift is sturdy b...

Page 12: ...stop button interrupts the power supply to the actuators and makes the actuators stop immediately in case of sudden danger Control panel with two buttons except handset Internal charger LCD display sh...

Page 13: ...the actuators and makes the actuators stop immediately in case of sudden danger press RED button turn RED button clockwise LOCKED UNLOCKED overload battery volume overused low battery battery low bli...

Page 14: ...the power plug WATERPROOF COVER when control is being used this cover can be used to prevent water ingress INSERT put the battery pack all the way down to position as Fig 2 while pressing the release...

Page 15: ...f the lift around or under the object Widen the base and engage the caster brakes Do not attempt to transfer a patient without prior approval of the person s nurse Also do not transfer without having...

Page 16: ...on the at section of the sling This will allow you to unroll the remainder of the sling from the other side of the user Once the sling has been positioned centrally feed the leg sections under the th...

Page 17: ...ir or chair then lower the patient onto the surface Note Reverse the above procedures when returning the user patient to bed A B A B C D Attach Loop A and D of the sling to Hook A on Spreader Bar atta...

Page 18: ...looseness of bolts or parts Replace any worn parts immediately To lubricate put a drop of oil on the following points when the ConvaLift is placed into service and every month thereafter Top of Mast...

Page 19: ...rust and crack CLEANING AS NEEDED ACTUATOR CONTROL BOX Make sure the control box is rmly af xed to the mast Make sure the actuator is secured to the Boom and mast with pins and key rings Make sure act...

Page 20: ...r will either go up or down but not both Replace your hand control as it is at the end of its life cycle Your control box may be malfunctioning There is a grinding sound inside the actuator when lifti...

Page 21: ...OT attempt to turn the Quick Release mechanism like a knob This will damage the Quick Release mechanism and actuator Manually activate Quick Release by pulling the RED lever with the arrow symbol in t...

Page 22: ...NOTES 22...

Page 23: ...s Actuator 2 years Parts including casters control box PCB pendant charger 2 years Batteries 1 year Weigh Scale 2 years Hydraulic pumps 1 year Reusable slings 6 months ConvaQuip Single Patient Slings...

Page 24: ...ConvaQuip LLC P O Box 3417 Abilene TX 79604 tel 325 677 4177 free 1 800 637 8436 www convaquip com ConvaQuip L L C...

Reviews: