background image

OWNER’S MANUAL  

|  

    

 

1

THANK YOU for choosing a Convair air 
conditioner. This appliance has been 
carefully engineered to bring you trouble-
free personal air conditioning. Please 
read this manual carefully so that you can 
take full advantage of the many benefi ts 
your Convair provides.

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, 
or lack of experience and knowledge, 
unless they have supervision or been 
given instruction in using the appliance by 
a person responsible for their safety. 

Children should be supervised to ensure 
that they do not play with the appliance.  
Do not place anything through the 
ventilating slots.

Be sure the appliance has been securely 
and correctly installed according to the 
installation instructions contained within 
this manual.

Personal Cooling

Your Convair refrigerated air conditioner 
is a portable unit that supplies cool air to 
a personal area within a room. It is not 
intended to function as a house or room 
air conditioner.

Energy Saving Tips

•  Do not locate the air conditioner where 

furniture or other objects can obstruct 

the air fl ow.

•  Keep curtains and blinds closed during 

the hottest part of the day.

•  Keep the fi lters clean.
•  Set the air conditioner to maximum 

cooling and high fan speed initially, 
then adjust to a comfortable setting.

•  Do not wait until the room is 

excessively hot before using the air 
conditioner.

Warranty

Convair air conditioners are warranted 
against faulty manufacture for 2 years 
after purchase. Please refer to page 12 
for more details on warranty.

INTRODUCTION

Summary of Contents for CP12CW3

Page 1: ...OWNER S MANUAL Supercool Portable Refrigerated Slimline Air Conditioner English CP12CW3...

Page 2: ...isposed of with household waste This product should be taken to your local recycling centre for safe treatment CONTENTS Introduction 1 Safety 2 Component Location 3 Installation 4 Control and Display...

Page 3: ...sure the appliance has been securely and correctly installed according to the installation instructions contained within this manual Personal Cooling Your Convair refrigerated air conditioner is a po...

Page 4: ...accordance with national wiring regulations Electrical Safety cont Caution Before connecting the electrical power cord to a power outlet check that the air conditioner voltage as shown on the rating l...

Page 5: ...ust outlet 9 Power supply cord 10 Cord storage 11 Water tank drain 12 Condenser air intake 13 Air lters 14 Handle 15 Remote control storage 16 Window kit 3 screws included 17 Exhaust hose 18 Hose end...

Page 6: ...ng the Exhaust Hose Step 1 Fit the hose end connectors to the exhaust hose by turning the hose end connectors counter clock wise to the exhaust hose as shown in Figure 5 Step 2 Open a window and t the...

Page 7: ...y Saving CONTROL AND DISPLAY 8 Air Conditioner Control Panel 1 10 12 11 6 7 5 2 8 3 4 6 4 13 5 9 Air Conditioner Remote Controller 3 1 2 3 7 9 8 9 COOL mode DEHUMIDIFY mode FAN mode ENERGY SAVINGS mod...

Page 8: ...n range 6 metres of the air conditioner Note If there are two of the same air conditioners installed they cannot be controlled separately When you operate either remote it will turn on both air condit...

Page 9: ...adjust the fan speeds Note In cooling mode the fan will continue to operate even if the compressor has turned off Note In dehumidifying mode the fan speed is locked at low and the temperature cannot...

Page 10: ...the air conditioner after a set period of time Timer for automatic start up is set by following the below steps with the air conditioner in stand by mode Timer for automatic shut down is set with the...

Page 11: ...C 3 Dry thoroughly before replacing 4 Take care to replace the lter back into the slot in the cooler Note Never operate the air conditioner without the lters MAINTENANCE Draining the air conditioner P...

Page 12: ...ath the air conditioner uneven The remote control does not work Is there anything obstructing the remote signal receiver Ensure to aim the remote at the air conditioner Ensure you are with the remote...

Page 13: ...r 430 Moisture Removal L hr 1 4 Refrigerant type Charge R410A 560g Max Pressure Suction MPa 2 0 Max Pressure Discharge MPa 5 0 Ingress Protection IPX0 Weight kg 34 0 Dimensions mm W 471 x D 355 x H 85...

Page 14: ...o misuse of the appliance Normal user maintenance Setting of controls Transit damage or Damage caused by user misuse tampering or failure to observe the care and special provisions in the instructions...

Page 15: ...al com PRIVACY NOTICE Seeley International Pty Ltd ABN 23 054 687 035 will use the personal information you provide us with to provide warranty support for the product you have purchased and to inform...

Page 16: ...leyinternational com It is the policy of Seeley International to introduce continual product improvement Accordingly speci cations are subject to change without notice Please consult with your dealer...

Reviews: