PORTABLE REFRIGERATED SLIMLINE AIR CONDITIONER - CP12CW3
|
10
Problem
Check/Cause/Remedy
Air conditioner does not operate
Is the air conditioner plugged in?
Is there a power failure?
FL error code fl ashing. Refer below.
Is the room temperature below the set temperature?
Ambient temperature is too high or too low. It is recommended
to use this air-conditioner between ambient temperatures of
10°C to 35°C.
The air conditioner has little
effect
Ensure that the room being cooled is not too large for the
stated capacity of the air conditioner.
Is there direct sunshine? Remember to close curtains or
blinds.
More people in the room will generate more heat
Is there something in the room producing excessive heat?
Are windows or doors open?
Is the exhaust fi tted correctly or obstructed? All exhaust air
needs to be completely removed from the room.
The air conditioner is not as cool
as it once was.
Are the air fi lters dusty or dirty, restricting the airfl ow?
Is the air inlet or outlet blocked.
Is the room temperature below the set temperature
The air conditioner is too noisy
Is the air conditioner positioned unevenly?
Is the fl oor beneath the air conditioner uneven.
The remote control does not
work
Is there anything obstructing the remote signal receiver?
Ensure to aim the remote at the air conditioner. Ensure you
are with the remote controls range.
Replace batteries.
The compressor will not turn.
It is possible that the overheat protection for the compressor is
on. Wait for it to reset.
Note: When changing between different modes (cooling to fan
or dry mode etc.) the compressor will turn off. A 3 minute delay
will occur before the compressor will turn on again.
E1 error code
Coil temperature sensor error. Disconnect the air conditioner
and reconnect. If error repeats, call a service agent.
E2 error code
Room temperature sensor error. Disconnect the air conditioner
and reconnect. If error repeats, call for a service agent.
E4 error code
Anti-freeze protection is active. This occurs when the coil
temperatures get too low. Operation will begin again once the
coil temperatures rise.
FL error code
Water tank is full. The WATER-FULL indicator will also be
active. Drain the air conditioner as shown in Maintenance
section.
Never try to dismantle the air conditioner yourself.
In case of problems that cannot be resolved using the above guide, or if service on your
dehumidifi er is required, please contact your dealer or designated service agent.